REC TRIGGER Input
58
Ch
apt
er 4
Re
co
rdin
g and Pl
ay
bac
k
• If a blank SRMemory card is inserted, the reel number
will increase by one from the last recorded file.
Example: If recording is performed on a blank card
after recording up to “D001CXXX_XXXXXXXX” on
the previously inserted card
The next recorded file will be named
“D002C001_XXXXXXXX.”
When you display the system, encoding, or file
name on the HOME screen while recording is
paused, the name of the file that will be created next
will flash on the screen.
• If you change the control panel settings, those settings
will be applied.
Example: If you change the camera ID and reel number
settings from the control panel for an SRMemory card
containing files up to “E003CXXX_XXXXXXXX”
If you change the camera ID to “F” and the reel
number to “001,” the next recorded file will be
named “F001CXXX_XXXXXXXX.” If you
change only the camera ID setting, the reel number
will change to “001.”
When a setting other than “OFF” is specified for
OTHERS >REC TRIGGER in the SYSTEM
Setup menu, REC START/STOP operations can
be controlled externally.
When REC TRIGGER is set to “SDI RMT”
By connecting the SDI output of an SR-R1, F65,
or camcorder that supports SDI remote output,
you can control REC START/STOP operations
from these devices. This setting does not allow
playback.
When REC TRIGGER is set to “SDI RMT
(Playable)”
This setting allows playback. However, if a REC
TRIGGER is input during playback, playback
must first be stopped before REC START is
enabled, thereby delaying the recording start time
by a few seconds.
When REC TRIGGER is set to “SYNCHRO
REC”
REC START/STOP can be synchronized when
used in conjunction with the PMW-F3.
The file names can also be synchronized.
For details, see “Connection to the PMW-F3”
(page 94).
When REC TRIGGER is set to “SYNCHRO
REC (Playable)”
This setting allows playback in SYNCHRO REC
mode. However, if a REC command for
SYNCHRO REC is input during playback,
playback must first be stopped before REC
START is enabled, so the Start TC will not be
synchronized.
REC TRIGGER Input