7-7
2-6-4. REC Y Level Check (MA-303 Board)
Mode
E-E
Signal
No signal
Measurement
Q301
E
or CN301 pin
6
point
Measuring
Oscilloscope
instrument
Specified
A=400 ± 120 mVp-p
value
[Check Method]
1)
Check that the record Y level A satisfies the specified value.
2-6-5. REC Chroma Level Check (MA-303 Board)
Mode
E-E
Signal
Color bar
Measurement
Q314
E
point
Measuring
Oscilloscope
instrument
A=140 ± 20 mVp-p (PAL SP)
Specified
A=160 ± 20 mVp-p (PAL LP)
value
A=160 ± 20 mVp-p (NTSC SP)
A=200 ± 20 mVp-p (NTSC LP)
[Adjusting Method]
1)
Check that the record chroma level A satisfies the specified
value.
Fig. 7-2-15.
2-6-6. Playback Level Check (MA-303 Board)
Mode
Playback
Signal
Alignment tape : Color bar portion
Measurement
LINE-1 OUT VIDEO terminal
point
(terminated at 75
Ω
)
Measuring
Oscilloscope
instrument
Specified
A=1.0 ± 0.18 Vp-p
value
[Check Method]
1)
Check that the playback level satisfies the specified value.
Fig. 7-2-17.
2-6-7. VCO Frequency Adjustment (MA-303 Board)
[Adjustment Object]
Adjust to set the character position on the screen.
Mode
E-E
Signal
Color bar
Measurement
IC401 pin
@§
point
Measuring
Oscilloscope (DC mode)
instrument
Adjustment
CT401
element
Specified
A=2.80 ± 0.05 Vdc
value
Fig. 7-2-18.
Fig. 7-2-16.
A
A
H
White (100%)
A
H
H
A
VDD=5.1Vdc
GND=0V
Summary of Contents for SLV-7700KME
Page 8: ...1 1 SLV 7700KME 7700KML SECTION 1 GENERAL This section is extracted from instruction manual ...
Page 9: ...1 2 ...
Page 10: ...1 3 ...
Page 11: ...1 4 ...
Page 12: ...1 5 ...
Page 13: ...1 6 ...
Page 14: ...1 7 ...
Page 15: ...1 8 ...
Page 16: ...1 9 ...
Page 17: ...1 10 ...
Page 18: ...1 11 ...
Page 19: ...1 12 ...
Page 20: ...1 13 ...
Page 21: ...1 14 ...
Page 22: ...1 15 ...
Page 23: ...1 16 ...
Page 24: ...1 17 ...
Page 25: ...1 18 ...
Page 26: ...1 19 ...
Page 27: ...1 20 ...
Page 28: ...1 21 ...
Page 29: ...1 22E ...