background image

21

Operating Systems

Backup Software Vendors

Phone Numbers

Windows 95

NovaStor

805-579-6700

DEC Unix

Cheyenne

516-484-5110

NovaStor

612-933-8790

Software Moguls

612-933-8790

Work Station Solutions

603-880-0080

SUN Unix

Legato

415-812-6000

NovaStor

818-707-9900

Software Moguls

612-933-8790

Sun Soft

310-348-8649

Work Station Solutions

603-880-0080

Solaris Unix

Cheyenne

516-484-3150

Legato

415-812-6000

NovaStor

818-707-9900

Software Moguls

612-933-8790

Sun Soft

310-348-8649

Work Station Solutions

603-880-0080

SCO Unix

Cheyenne

516-484-3150

Legato

415-812-6000

Software Moguls

612-933-8790

Work Station Solutions

603-880-0080

NCR Unix

NovaStor

818-707-9900

Work Station Solutions

603-880-0080

HP Unix

Cheyenne

516-484-3150

NovaStor

818-707-9900

Work Station Solutions

603-880-0080

AIX Unix

Cheyenne

516-484-3150

Legato

415-812-6000

NovaStor

818-707-9900

Software Moguls

612-933-8790

Work Station Solutions

603-880-0080

Interactive Unix

Sun Soft

310-348-8649

SGI Unix

Software Moguls

612-933-8790

Work Station Solutions

603-880-0080

Novell UNIXware

Novell

801-263-3500

Novell NLM

Arcada

407-263-3500

Avail Systems

303-444-4018

Cheyenne

516-484-3150

Columbia Data Products

407-682-0265

Creata

909-595-8811

Legato

415-812-6000

NovaStor

818-707-9900

Novell

801-419-5544

Palindrome

708-505-3300

Performance Tech

210-979-2110

ST. Bernard Software

619-676-2277

Symantec

310-449-4156

Sytron

508-898-0100

Banyan

Performance Tech

210-979-2110

Lantastic

NovaStor

818-707-9900

Amiga

Moonlighter

407-384-9484

RS6000

Legato

415-812-6000

NovaStor

818-707-9900

Software Moguls

612-933-8790

Summary of Contents for SDT 11000 - DDS Tape Drive

Page 1: ...3 866 090 04 1 1998 Sony Corporation DDS Tape Drive SDT 10000 Series SDT 11000 Series User s Guide ...

Page 2: ...rüstung erfüllt die Europäischen EMC Bestimmungen für die Verwendung in folgender folgenden Umgebung en Wohngegenden Gewerbegebiete Leichtindustriegebiete Diese Ausrüstung erfüllt die Bestimmungen der Norm EN55022 Klasse B Contents Introduction 4 Product Features 4 Precautions 5 Installation 6 SCSI Connection Setting the SCSI ID Option Switches 6 Option Switches DIP Switch 7 Mounting Holes 8 Remod...

Page 3: ...rough Read After Write an additional level of Error Correction Code and other features The Sony SDT 10000 SDT 11000 drive stores data on tape using a standard format called DDS Digital Data Storage DDS 4 DDS 3 DDS 2 DDS DC and DCLZ formats These formats are used by many other DDS tape drive manufacturers providing a broad range of compatible tape drives The Sony SDT 10000 SDT 11000 is fully READ a...

Page 4: ...pports SCSI 2 Sequential access Devices Command Set Read After Write RAW Frame Rewrite Function Three Levels of Error Correction Code ECC Quick Search Forward 115 times Reverse 155 times normal DDS 4 Read Write speed Random Read N Group Write Option DDS 2 DDS and DDS DC only Dual Partition Option SCSI Disconnection Arbitration Assuming 2 1 compression Actual capacity and transfer rate may vary sin...

Page 5: ...dden increase in temperature a malfunction may occur Do not turn off the drive while a tape is inside the drive Transportation Keep the original packing materials for possible future shipments of the drive Be sure to remove any tapes from drive prior to transportation After removing the drive from the computer repack the drive into its original packaging Notice of SCSI Termination This SDT 10000 S...

Page 6: ... 3 2 1 GND GND 12V 5V Power Connector 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 SCSI ID SCSI ID P E R 3 2 1 0 Parity Enable Disable Note CLOSE Jumper OPEN Jumper not installed Don t care Parity Enable Reserved SCSI ID 3 SCSI ID 2 SCSI ID 1 SCSI ID 0 Jumpers SCSI 68 pin connector Non Shielded ...

Page 7: ...erminator Power Definition OFF No provided ON Provided DC Control 1 DC Control 2 Definition OFF OFF Compression disabled at power on The host is allowed to control compression OFF ON Compression disabled at power on The host is not allowed to control compression ON OFF Compression enabled at power on The host is allowed to control compression ON ON Compression enabled at power on The host is not a...

Page 8: ... 0 20 in 5 0 3mm depth 0 12 in 3 M3 depth 3mm 3 70 in 94 0 3mm 4 00 in 101 6 0 5mm 1 22 in 31 0 3mm 1 65 in 42 0 3mm 2 76 in 70 0 3mm depth 0 12 in 6 M3 depth 3mm 2 36 in 60 0 3mm 3 54 in 90 0 3mm 5 75 in 146 0 5mm 0 15 in 3 8 0 5mm 0 83 in 21 0 3mm 0 20 in 5 0 3mm 1 62 in 41 2 0 5mm depth 0 12 in 3 M3 depth 3mm ...

Page 9: ...mm 2 76 in 70 0 3mm 3 12 in 79 2 0 3mm 2 00 in 50 7 0 3mm 5 50 in 139 6 0 4mm 5 87 in 149 0 5mm depth 0 12 in 6 M3 depth 3mm 4 M3 3 12 in 79 2 0 3mm 1 87 in 47 5 0 3mm 0 39 in 9 9 0 3mm 0 86 in 21 8 0 3mm 4 M3 3 12 in 79 2 0 3mm 1 87 in 47 5 0 3mm 1 62 in 41 2 0 5mm 0 86 in 21 8 0 3mm 0 39 in 9 9 0 3mm 0 28 in 7 0 3mm ...

Page 10: ...Model to 3 5 Model You can remodel the SDT 10000 R and the SDT 11000 R 5 25 model to the SDT 10000 and the SDT 11000 3 5 model yourself 1 Remove the 2 screws for each side rail 2 Take the side rail off Side Rail L Side Rail R ...

Page 11: ...11 Orientation 10 10 10 10 10 10 10 10 ...

Page 12: ...12 Operation Location of 3 LEDs There are three LED indicators BUSY TAPE and STATUS and an EJECT button on the front panel of the unit Front Panel for 3 5 Standard Height BUSY TAPE STATUS ...

Page 13: ...ne Loaded None SCSI Loaded None SCSI Drive Loaded None Loaded Write Protected None Loaded Cleaning Tape at EOM Loaded Error Rate Warning Cleaning Request Selftest Failure Waiting for Reset Waiting for Eject Not defined 3 5 sec on 0 5 sec off 1 pulse 0 25 sec on 2 pulse 0 25 sec on 0 5 sec off off on 0 25 sec on 0 25 sec off LED Indication for Drive Status ...

Page 14: ...sponse to a SCSI Unload Command or by pressing the eject button By pressing Eject button the tape goes to BOM the drive unthreads it and ejects the cassette from the slot Write protecting a Cassette Cassettes can be write protected by sliding the tab on the back of the cassette open In this state data can be read from the tape but not written onto it Using your fingernail push the switch in the di...

Page 15: ... the drive from the chassis or enclosure to allow access to the bottom and left side of the drive 2 Remove the drive s top cover to monitor the degree of tape slack throughout the process Note Never touch the inside of the drive when the top cover is opened Otherwise it may cause a trouble 3 Rotate the Loading Threading motor clockwise with a small screwdriver ex Phillips No 1 put into the plastic...

Page 16: ...16 4 Continue the procedure until the tape is lifted out of the drive mechanism and ejected 5 Return the drive to a service station for repair ...

Page 17: ...ject No Operation Restore Pointers Save Data Pointer Supported SCSI Commands Erase Inquiry Load Unload Locate Log Select Log Sense Mode Select 6 Mode Sense 6 Prevent Allow Medium Removal Read Read Block Limits Read Buffer Read Position Receive Diagnostic Results Release Unit Report Density Support Report Luns Request Block Address Request Sense Reserve Unit Rewind Seek Block Send Diagnostic Space ...

Page 18: ...e The sound meter on A scale is located 1m in front of the center of the drive front panel Shock Operating No Data Loss Half Sine Performance 5 G Peak 3 ms 3 axes 3 directions Interval 10 seconds Non Operating No Device Damage Half Sine 90 G Peak 3 ms 30 G Peak 11 ms 3 axes 3 directions Specification Product Specifications Dimensions 3 5 Standard Height 5 25 Half Height Height 41 2 mm 1 62 in 41 2...

Page 19: ...of data loss Temperature and Humidity Range Temperature Operating 5 C to 40 C T 10 C h Non Operating mech 40 C to 70 C T 20 C h Non Operating tape 40 C to 45 C T 20 C h Humidity Operating 20 to 80 RH non condensing Maximum wet bulb temperature 26 C Non Operating mech 5 to 95 RH RH 30 h Non Operating tape 20 to 80 RH RH 30 h Power Requirements Voltage Max Ripple Current Typical Maximum 5 V 5 100 mV...

Page 20: ...7 869 6700 Corel 613 728 8200 NovaStor 805 579 6700 Palindrome 708 505 3300 ST Bernard Sofware 619 676 2277 Sytron 508 898 0100 Tapedisk 715 235 3388 Macintosh Cheyenne 516 484 5110 Corel 613 728 8200 Dantz 510 253 3000 NovaStor 805 579 6700 OS 2 Cheyenne 516 484 5110 Corel 613 728 8200 IBM 800 426 3333 NovaStor 805 579 6700 Sytron 407 333 7500 Windows Arcada 407 333 7500 Cheyenne 516 484 5110 Cor...

Page 21: ...880 0080 HP Unix Cheyenne 516 484 3150 NovaStor 818 707 9900 Work Station Solutions 603 880 0080 AIX Unix Cheyenne 516 484 3150 Legato 415 812 6000 NovaStor 818 707 9900 Software Moguls 612 933 8790 Work Station Solutions 603 880 0080 Interactive Unix Sun Soft 310 348 8649 SGI Unix Software Moguls 612 933 8790 Work Station Solutions 603 880 0080 Novell UNIXware Novell 801 263 3500 Novell NLM Arcad...

Page 22: ...9 FAX 416 499 8541 Sony Computer Peripherals Compornents Europe URL http www sonyisstorage com Electronics Devices Marketing Singapore A division company of Sony Electronics S Pte Ltd Enterprise Storage Solutions Dept 2 International Business Park 01 10 Tower One The Strategy Singapore 609930 TEL 65 6544 8000 FAX 65 6544 7390 Sony Corporation of Hong Kong Ltd Computer Peripheral Sales Marketing Di...

Page 23: ...564 A C N 001 215 354 URL http www sony com au home asp E mail informatica ssp br sony com Sony Chile Ltda Av Kennedy 8017 Las Condes Santiago Chile TEL 02 210 6000 FAX 02 210 5417 Sony Taiwan Limited Computer Peripheral Dept Electronic Devices Marketing Taiwan Company Rm 1506 Top FL Chia Hsin Bldg No 96 Sec 2 Chung Shan N Rd Taipei Taiwan TEL 886 2 2522 3286 FAX 886 2 2562 4587 Sony Korea Corpora...

Page 24: ...Printed in Japan ...