7
Option Switches (DIP Switch)
UNLO
AD
1
2
3
4
5
6
7
8
O
N
1
2
3
4
5
6
7
8
O
N
1 Reserved (OFF)
2 Reserved (OFF)
3 Reserved (OFF)
4 Reserved (OFF)
5 Terminator Power (ON)
6 Reserved (OFF)
7 DC Control-1 (ON)
8 DC Control-2 (OFF)
( ) . . . default setting
Terminator Power
Definition
OFF
No provided
ON
Provided
DC Control-1
DC Control-2
Definition
OFF
OFF
Compression disabled at power-on. The host is
allowed to control compression.
OFF
ON
Compression disabled at power-on. The host is
not allowed to control compression.
ON
OFF
Compression enabled at power-on. The host is
allowed to control compression.
ON
ON
Compression enabled at power-on. The host is
not allowed to control compression.