4-10
SAL1680Z (Vario-Sonnar DT 3.5-4.5/16-80 ZA) (Vario-Sonnar T
*
DT 16-80mm F3.5-4.5 ZA)
4-1-3. Connection of Finished Inspection JIG and Lens Adjustment Program (ActuatorChecker)
Note:
Confirm “4-1-2. Lens Adjustment Program (ActuatorChecker)” has been completed before this procedure is executed.
Equipment
• Personal Computer
• Finished Inspection JIG (AC100 V only)
• Lens Adjustment Program (ActuatorChecker.exe)
1.
Connect equipment and checking lens as shown Fig.4-1-20.
Fig.4-1-20
2.
Turn on the finished inspection JIG.
3.
Turn on the personal computer.
4.
Start up “ActuatorChecker.exe” from an arbitrary folder, conform that start up program normally.
Note:
Turn off the finished inspection jig after use.
Finished Inspection JIG
Lens