— 4 —
1.
HOW TO RETURN THE PINCH
ROLLER, GUIDE ROLLER AND
ELEVATOR CAM TO STOP MODE
1)
Remove the VHS MD assembly from the machine. (Refer to
section 2-4. Removal.)
2)
Rotate the worm gear-1 of the cam motor beneath the MD
assembly in the direction arrow
A
using a screw driver tip.
Fig. 1
2.
HOW TO RETURN A TAPE INTO
CASSETTE HALF
A tape can be rewound into a cassette half by rotating the
flywheel-1 of the capstan motor in the direction of
A
with hand.
Fig. 2
Flywheel-1
Timing belt
Front side
3.
HOW TO REMOVE A CASSETTE
FROM A MACHINE IF A CASSETTE
IS LEFT IN A MACHINE IN TROUBLE
Execute the section 2, and keep rotating the flywheel-1.
When executing section 1 to 3, take care that a tape slack
should not be caught by a mechanism or a tape should not
be damaged.
4.
HOW TO REMOVE DRUM
ASSEMBLY
Fig. 3
1
Worm gear-1
Front side of the
machine
Cam motor
A
Drum assembly
1
Remove connector
CN260 from RP-217
board.
2
Screw +P3
×
8
SERVICE NOTE
SLV-E325EG/E475EG/E570EE/E570EG/E620B/E620VC/E720B/E720BZ/E720EE/
E720EG/E720EX/E720NC/E720NP/E720UX/E720VC/E720VP/E725NC