SAFETY CHECK-OUT
After correcting the original service problem,
perform the following safety checks before
releasing the set to the customer :
Check the metal trim, “metallized” knobs, screws,
and all other exposed metal parts for AC
leakage. Check leakage as described below.
LEAKAGE TEST
The AC leakage from any exposed metal part to
earth ground and from all exposed metal parts to
any exposed metal part having a return to
chassis, must not exceed 3.5 mA. Leakage
current can be measured by any one of three
methods.
1. A commercial leakage tester, such as the
Simpson 229 or RCA WT-540A. Follow the
manufacturers’ instructions to use these
instruments.
2. A battery-operated AC milliammeter. The
Data Precision 245 digital multimeter is
suitable for this job.
3. Measuring the voltage drop across a resistor
by means of a VOM or battery-operated AC
voltmeter. The “limit” indication is 5.25 V, so
analog meters must have an accurate low-
voltage scale. The Simpson 250 and Sanwa
SH-63Trd are examples of a passive VOM
that is suitable. Nearly all battery operated
digital multimeters that have a 20 V AC range
are suitable. (See Fig. A)
To Exposed Metal
Parts on Set
Fig A. Using an AC voltmeter to check AC leakage.
AC
voltmeter
(5.25V)
Earth Ground
0.15 µF
1.5 k
Z
Summary of Contents for RM-PJM50
Page 1: ...WORLD SERVICE MANUAL MODEL VPL FX50 LCD DATA PROJECTOR MODEL RM PJM50 DEST WORLD DEST ...
Page 4: ......
Page 28: ...1 20 VPL FX50 Sony Corporation Printed in Japan ...
Page 29: ...1 21 VPL FX50 ...
Page 32: ...1 24 VPL FX50 ...
Page 33: ...1 25 VPL FX50 ...
Page 34: ...1 26 VPL FX50 ...
Page 35: ...1 27 VPL FX50 ...
Page 37: ...1 29 VPL FX50 ...
Page 38: ...1 30 VPL FX50 ...
Page 48: ......
Page 60: ......
Page 120: ......
Page 130: ......