11
Connect the RS-232C port to external equipment as follows:
RS-232C port
External equipment
Pin No.
Pin No.
1
1
2
2
3
3
4
4
5
5
6
6
20
20
7
7
RS-232C Port
Connection
Use the cables with the following specifications for
connection between the RS-232C port and the external
equipment.
Connector:
25-pin D-SUB (inch standard)
Cable:
Multicore shielded cable for data
communications (min. 8 cores)
Cable length:
Less than 15 m
Pin No.
1
2
3
4
5
6
7
20
Name
FG
TXD
RXD
RTS
CTS
DSR
SG
DTR
Function
Frame ground
Transmit data
Receive data
Request to send
Clear to send
Data set ready
Signal ground
Data terminal ready
NOTE
You can format the same preceeding data as PVS-880S
and the PVS-1680S. However, do not set more than
twelve inputs and four outputs for the Crosspoint
buttons to prevent damage to the hardware.
The PVS-1240S can be controlled from equipment with the RS-232C port, such as the SRP-C5000 system controller, or from a
personal computer via its RS-232C port.
Data Format
Data format is set as follows:
For communication protocol, refer to the separate “PVS-1240S RS-232C Interface Manual” available from a Sony office in your
area.
Mode:
Asynchronous
Data length:
8 bits
Baud rate:
9600 bps
Parity check:
Odd parity
Stop-bit length:
1 bit
Bit sequence:
Send from the least-significant bit.
Connector-Pin Assignment
The RS-232C port is a 25-pin D-SUB connector (female).
The pin assignment is as follows:
(continued)
Summary of Contents for PVS-1240S
Page 14: ...14 ...