25
MZ-NE410/NE410CK
• Adjustment Method of CD and MO Overall Adjustment
Mode
1. Set the test mode (see page 13).
2. Press the
.
key to activate the overall adjustment mode.
3. Insert CD disc in the set, and press the
.
key to set the
CD overall adjustment mode. Automatic adjustments are made.
4. In case of CD overall adjustment NG, readjust from the NV
reset (see page 18), The temperature correction (see page 18)
may be omitted.
5. If OK through the CD overall adjustments, then perform MO
overall adjustments.
6. Insert MO disc in the set, and press the
>
key to set the
MO overall adjustment mode. Automatic adjustments are
made.
7. In case of MO overall adjustment NG, readjust from the NV
reset (see page 18). The temperature correction (see page 18)
may be omitted.
8. If OK through the MO overall adjustments, press the
x
/CANCEL
key to return to the test mode and terminate the
overall adjustment mode.
• Overall Adjustment error message
The following message will be displayed if adjustment
procedure is mistaken in the CD and MO overall adjustment.
• CD and MO Overall Adjustment Items
1. CD overall adjustment items
Item No.
Description
761
VC,VR power supply H/L selection
300
HPIT setting . servo OFF
561
SLED inward movement
562
SLED outward movement
High reflection electrical offset adjustment
312
Laser ON . Focus UP . vc correction
ALFA offset adjustment
313
IJ offset adjustment
314
FE offset adjustment
HPIT adjustment
320
Focus servo ON
324
TE offset adjustment 1
321
TE gain adjustment
328
TWPP gain adjustment
324
TE offset adjustment 1
332
TE offset adjustment 2
330
Tracking servo ON
336
ABCD gain adjustment
337
KF gain correction
338
RF gain adjustment
344
FCS gain adjustment
345
TRK gain adjustment
521
Two-axis sensitivity (outer position)
522
Two-axis sensitivity (outer position)
300
HPIT setting . servo OFF
Message
Display timing
During CD/MO/DISC
CLOSE!
automatic distinction
overall adjustment
During MO/DISC
Set CD!
automatic distinction
overall adjustment
During offset adjustment
Set MO!
During offset adjustment
During CD/MO/DISC
NoTmp!
automatic distinction
overall adjustment
Description
DISC is not inserted.
• CD overall adjustment is not
completed in the MO overall
adjustment.
• CD and MO overall
adjustment is not completed
in the offset adjustment.
MO overall adjustment is not
completed in the offset
adjustment
Temperature correction
(item number 015)
is not finished.
Set LCD display
M O O K
000
***
: NG item number.
Set LCD display
* * * N G
000
XXX
: Item number for which
an adjustment is being executed.
Set LCD display
M O R U N
XXX
Set LCD display
C D O K
000
***
: NG item number.
Set LCD display
* * * N G
000
XXX
: Item number for which
an adjustment is being executed.
Set LCD display
C D R U N
XXX
Set LCD display
A s s y 1 1
000