16
MZ-E510
• Adjustment Method of CHGV_L
(item number: 751)
Note:
Remove the rechargeable battery.
1. Connect a digital voltmeter to the TP953(BATT
+
) and
TP954(BATT
−
) on the MAIN board, and adjust
[VOL +]
key
(voltage up) or
[VOL --]
key (voltage down) so that the voltage
becomes 1.35
±
0.01V.
2. Press the
u
key on the set or the
key on the remote
commander to write the adjusted value.
Adjustment and Connection Location: MAIN board
(see page 17)
• Adjustment Method of CHGV_H
(item number: 752)
Note:
Remove the rechargeable battery.
1. Connect a digital voltmeter to the TP953(BATT
+
) and
TP954(BATT
−
) on the
MAIN board, and adjust
[VOL +]
key (voltage up) or
[VOL --]
key (voltage down) so that the voltage becomes 1.80
±
0.01V.
2. Press the
u
key on the set or the
key on the remote
commander to write the adjusted value.
Adjustment and Connection Location: MAIN board
(see page 17)
• Adjustment Method of CIL (Charge current)
(item number: 753)
Note:
Remove the rechargeable battery.
1. Make a solder bridge to short TAP951 on the MAIN board (in
order to connect R964(47
Ω
) between TP953(BATT
+
) and
TP954(BATT
−
))
2. Turn on the power.
3. Set the manual mode of the test mode and set the item number
753 (see page 10).
4. Connect a digital voltmeter to the TP953(BATT
+
) and
TP954(BATT
−
) on the MAIN board, and adjust the
[VOL +]
key (voltage up) or
[VOL --]
key (voltage down) so that the
voltage becomes 1.41
±
0.02V.
5. Press the
u
key on the set or the
key on the remote
commander to write the adjusted value.
6. Turn off the power and open the solder bridge on TAP951 on
the MAIN board.
Adjustment and Connection Location: MAIN board
(see page 17)
• Adjustment Method of CIH (Charge current)
(item number: 754)
Note:
Remove the rechargeable battery.
1. Make a solder bridge to short TAP952 on the MAIN board (in
order to connect R965(10
Ω
) between TP953(BATT
+
) and
TP954(BATT
−
))
2. Turn on the power.
3. Set the manual mode of the test mode and set the item number
754 (see page 17).
4. Connect a digital voltmeter to the TP953(BATT
+
) and
TP954(BATT
−
) on the MAIN board, and adjust the
[VOL +]
key (voltage up) or
[VOL --]
key (voltage down) so that the
voltage becomes 1.40
±
0.02V.
5. Press the
u
key on the set or the
key on the remote
commander to write the adjusted value.
6. Turn off the power and open the solder bridge on TAP952 on
the MAIN board.
Adjustment and Connection Location: MAIN board
(see page 17)
Remote commander LCD display
**
: Adjusted value
ChgV L **
751
digital
voltmeter
MAIN board
TP953 (BATT+)
TP954 (BATT-)
Remote commander LCD display
**
: Adjusted value
ChgV H **
752
digital
voltmeter
MAIN board
TP953 (BATT+)
TP954 (BATT-)
Remote commander LCD display
**
: Adjusted value
CIL **
753
digital
voltmeter
MAIN board
TP953 (BATT+)
TP954 (BATT-)
TAP951
R964 (47
Ω
)
Remote commander LCD display
**
: Adjusted value
CIH **
754
digital
voltmeter
MAIN board
TP953 (BATT+)
TP954 (BATT-)
TAP952
R965 (10
Ω
)