1-19 (E)
MVS-6520
D702 (G-1): INET ACT
Blinks in green during data transmission/reception when
Ethernet1 on CPU (CPU-DP module) is linked with the
CA-85 board.
D701 (G-1): INET LINK
Lit in green when Ethernet1 on CPU (CPU-DP module) is
linked with the CA-85 board.
D704 (H-1): FM ACT
Blinks in green during data transmission/reception when
Ethernet2 on CPU (CPU-DP module) is linked with the
external panel
D703 (H-1): FM LINK
Lit in green when Ethernet2 on CPU (CPU-DP module) is
linked with the external panel.
D705 (G-1): UTIL A/L
Lit in green when Ethernet3 on CPU (CPU-DP module) is
linked with the external device, and blinks in green during
data transmission/reception.
D902 (H-1): PCIE ACT
Blinks in green during transmission/reception when PCI
Express signal on CPU (CPU-DP module) is linked with
IC902 (SATA CONTROLLER).
D901 (H-1): PCIE CON
Lit in green when PCI Express signal on CPU (CPU-DP
module) is connected to IC902 (SATA CONTROLLER).
Switch
S501 (K-1): RST switch
Reset switch of the MY-119 board.
When this switch is pressed, CPU on the MY-119 board is
initialized.
S601 (K-1): MON switch
Monitor switch used when the maintenance with terminal
is performed.
LED on CPU-DP module
Refer to “LED on CPU-DP module” in “1. CA-85 board”.
Switch on CPU-DP module
Refer to “Switch on CPU-DP module” in “1. CA-85
board”.
LED
D203 (C-1):
+
12V
+
12V power status indication.
Lit in green when
+
12V is supplied.
D404 (C-1):
+
5V (SSD)
+
5V power (for SSD) status indication.
Lit in green when
+
5V is supplied.
D401 (C-1):
+
3.3V
+
3.3V power status indication.
Lit in green when
+
3.3V is supplied.
D405 (D-1):
+
2.5V
+
2.5V power status indication.
Lit in green when
+
2.5V is supplied.
D406 (C-1):
+
1.5V
+
1.5V power status indication.
Lit in green when +1.5V is supplied.
D402 (C-1):
+
1.2V (CAD)
+
1.2V power (IC1: CADEC FPGA) status indication.
Lit in green when
+
1.2V is supplied.
D403 (C-1):
+
0.9V (FMS)
+
0.9V power (IC2: FMS FPGA) status indication.
Lit in green when
+
0.9V is supplied.
D1301 (D-1): OTHER PWR (0.75V, 1,0V, 1,2V, 1.8V)
Other Regulator power status indication.
Lit in green when other Regulator power is supplied.
D1303 (D-1): CONF ERR (IC1: CADEC FPGA)
Configuration error indication of CADEC FPGA in IC1.
When this LED is lit in red, CADEC FPGA in IC1 may not
operate normally.
D1201 (D-1): CONF ERR (IC2: FMS FPGA)
Configuration error indication of FMS FPGA in IC2.
When this LED is lit in red, FMS FPGA in IC2 may not
operate normally.
D1304 to 1319 (E-1):
CPU status (forming 7SEG LED of two-digit display)
Status indication of CPU (CPU-DP module) on the board.