32
Details of function
:
This is the command to send “REC REMAIN DATA”, recordable re-
main time information of the current disc, to MDS.
When this command is sent in the stop mode, MDS sends “REC RE-
MAIN REQ”, recordable remain time information of the current disc.
MDS returns collect value only when disc is recordable and TOC on
the disc has been read and in the stop mode.
Example of transmission packet:
Check remain time for recording.
7EH, 08H, 05H, 47H, 20H, 54H, 01H, FFH
6.41
NAME REMAIN REQ
Function
:
Check remaining inputtable name of the disc.
Data length
:
4 bytes
Data
:
20H, 55H, 00H, Track No.
Track: 0(
00H
) to 255(
FFH
)
Details of function
:
This is the command to send out “NAME REMAIN REQ”, the informa-
tion of remaining inputtable name of the current disc, to MDS.
At this command in the stop mode, MDS sends out the maximum num-
ber of inputtable characters when you change the name of specified
track or disc.
This means, it sends out the quantity of name area + unused area
which the specified track number reserves.
In case of specifying the track number as 0(
00H
), it sends out the
quantity of name area + unused area of the disc.
Example of transmission packet
:
Check the number of remaining inputtable characters when the name
of the first track is changed.
7EH, 09H, 05H, 47H, 20H, 55H, 00H, 01H, FFH
6.42
DISC NAME WRITE
Function
:
Write name in disc.
Data length
:
Maximum 19 bytes
Data
:
The first packet
:
20H, 70H, 01H,
NameData