24
(Caution: If the same numbers are specified in Track A# and Track B#,
it may cause malfunction. Please specify a different track number in
each.)
Details of function
:
This is the command to complete combining tracks from rehearsal.
When this command is sent while combine rehearsal is being carried
out by “COMBINE MODE REQ” command, MDS will complete com-
bining two tracks.
This command must be sent during combine rehearsal by “COMBINE
MODE REQ”. If it is sent during other than combine rehearsal, some-
times it may cause malfunction.
This command can function for tracks are not side by side.
Example of transmission packet
:
Carry out combine during combine rehearsal of the 2nd track and 12th
one.
7EH, 08H, 05H, 47H, 0AH, 0AH, 02H, 0CH, FFH
6.25
EDIT MODE CANCEL
Function
:
To stop rehearsal
Data length
:
2 bytes
Data
:
0AH, 03H
Details of function
:
This is the command to stop divide/combine rehearsal.
When this command is sent during rehearsal of “DIVIDE MODE REQ”
or “COMBINE MODE REQ” command, rehearsal is stopped and play-
back restarts from the point rehearsal has being carried out.
This command must be sent during rehearsal.
If it is sent during other than rehearsal, sometimes it may cause mal-
function.
Example of transmission packet
:
Stop track divide rehearsal.
7EH, 07H, 05H, 47H, 0AH, 03H, FFH
6.26
ERASE REQ
Function
:
To erase track
Data length
:
3 bytes