5-15
9. White Balance Check
Subject
Clear chart
(Color bar standard picture frame)
Filter
ND filter 1.0 and 0.3
Measurement Point
Display data of page: 1
Measuring Instrument
Adjustment remote commander
Specified Value
R-Y data:
FC to FF or 00 to 04 (Note1)
B-Y data:
FC to FF or 00 to 04 (Note1)
Light level data:
Without ND filter:
0E10 or more (Note2)
With ND filter 1.3:
0D00 or less (Note2)
Note 1:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
R-Y data
B-Y data
Note 2:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Light level data
Checking method:
1)
Check that the lens is not covered with the ND filter.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: E, address: 11, set data: 15, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 0, address: 03, and set data: 02.
5)
Select page: 2, address: 10, and set data: 58.
6)
Select page: 2, address: 56, and set data: 56.
7)
Select page: 2, address: 01, set data: 0F, and press the PAUSE
button.
8)
Select page: 1, and check that the R-Y data satisfies the specified
value and the B-Y data satisfies the specified value. (Note1)
9)
Select page: 0, address: 03, and set data: 06.
10) Select page: 1, and check that the light level data satisfies the
specified value. (Note2)
11) Place the ND 1.3 filter on the lens.
12) Select page: 1, and check that the light level data satisfies the
specified value. (Note2)
Processing after Completing Adjustments
1)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
2)
Select page: 2, address: 10, and set data: 00.
3)
Select page: 2, address: 56, and set data: 00.
4)
Select page: E, address: 11, set data: 18, and press the PAUSE
button.
5)
Select page: 0, address: 01, and set data: 00.
6)
Select page: 0, address: 03, and set data: 00.
10. Strobe Light Level Adjustment
Adjust the minimum gain when the strobe light flashes.
Subject
Clear chart
(Color bar standard picture frame)
Measurement Point
Display data of page : 1
Measuring Instrument
Adjustment remote commander
Adjustment Page
E
Adjustment Address
81
Specified Value
01E7 to 0267
Note:
Displayed data of page 1 of the adjustment remote commander.
1 :XX:XX
Object data
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: E, address: 70, set data: 03, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: E, address: 71, set data: 00, and press the PAUSE
button.
4)
Select page: 2, address: 10, and set data: 58.
5)
Select page: 2, address: 01, set data: 9D, and press the PAUSE
button.
6)
Select page: 1, and read the display data (Note). If the display
data lies within the “0207” to “0247” range, perform
“Processing after Completing Adjustments”.
7)
Select page: E, address: 81, change the data, and press the
PAUSE button.
8)
Select page: 1, and check that the display data lies within the
“0207” to “0247” range. If not, repeat steps 7) to 8).
9)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button.
10) Select page: 2, address: 01, set data: 9D, and press the PAUSE
button.
11) Select page: 1, and check that the display data satisfies the
specified value.
Processing after Completing Adjustments
1)
Select page: E, address: 70, set data: 00, and press the PAUSE
button of the adjustment remote commander.
2)
Select page: E, address: 71, set data: 00, and press the PAUSE
button.
3)
Select page: 0, address: 01, and set data: 00.
4)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
5)
Select page: 2, address: 10, and set data: 00.
Summary of Contents for Mavica MVC-FD91
Page 8: ...1 1 MVC FD91 SECTION 1 GENERAL This section is extracted from instruction manual ...
Page 9: ...1 2 ...
Page 10: ...1 3 ...
Page 11: ...1 4 ...
Page 12: ...1 5 ...
Page 13: ...1 6 ...
Page 14: ...1 7 ...
Page 15: ...1 8 ...
Page 16: ...1 9 ...
Page 17: ...1 10 ...
Page 18: ...1 11E ...
Page 27: ...MVC FD91 SECTION 3 BLOCK DIAGRAMS 3 1 OVERALL BLOCK DIAGRAM 3 1 3 2 3 3 MVC FD91 ...
Page 32: ...MVC FD91 3 6 POWER BLOCK DIAGRAM 3 18 3 19 3 20E IC301 0 8Vp p 2 2µsec IC301 2 0Vp p 2 1µsec ...
Page 36: ...MVC FD91 4 12 4 13 4 14 STEADY SHOT CONTROL VP 49 VP 49 BOARD 1 IC237 2 8Vp p 12MHz ...