5-5
Adjusting page
Adjusting Address
Adjusting page
Adjusting Address
F
00 to FF
E
00 to FF
Address
00 to 0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
Initial value
00
80
88
AD
C2
CD
Remark
Test mode
Fixed data-1
Fixed data-2
Fixed data-1
(Initialized data)
Battery end adj.
Address
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
40
41
42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
Initial value
BB
6F
77
7A
DB
6F
97
78
7C
Remark
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
Bright adj. (LCD)
Color adj. (LCD)
White balance adj. (LCD)
Contrast adj. (LCD)
VCO adj. (LCD)
V-COM adj. (LCD)
D range adj. (LCD)
V-COM level adj. (LCD)
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
(Initialized data)
1-2. INITIALIZATION OF F, E PAGE DATA
1. Initializing the F, E Page Data
Note:
If the F, E page data is initialized, all adjustments must be performed
again.
Initializing Method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 00, and set data: 2D.
3)
Select page: 3, address: 01, set data: 2D, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 3, address: 00, and check that the data is “00”.
5)
Perform “Modification of F, E Page Data”.
2. Modification of F, E Page Data
If the F, E Page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note :
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of F, E Page data
1)
Select page: 3, address: 00, and set data: 29.
2)
Select page: 3, address: 01, and set data: 29, and press the
PAUSE button of the adjustment remote commander.
3)
Perform all adjustments.
3. F Page Table
Note:
Fixed data-1 : Initialized data. (Refer to “1. Initializing the F, E
Page Data”.)
Fixed data-2 : Modified data. (Refer to “2. Modification of F, E
Page Data”.)
Summary of Contents for Mavica MVC-FD91
Page 8: ...1 1 MVC FD91 SECTION 1 GENERAL This section is extracted from instruction manual ...
Page 9: ...1 2 ...
Page 10: ...1 3 ...
Page 11: ...1 4 ...
Page 12: ...1 5 ...
Page 13: ...1 6 ...
Page 14: ...1 7 ...
Page 15: ...1 8 ...
Page 16: ...1 9 ...
Page 17: ...1 10 ...
Page 18: ...1 11E ...
Page 27: ...MVC FD91 SECTION 3 BLOCK DIAGRAMS 3 1 OVERALL BLOCK DIAGRAM 3 1 3 2 3 3 MVC FD91 ...
Page 32: ...MVC FD91 3 6 POWER BLOCK DIAGRAM 3 18 3 19 3 20E IC301 0 8Vp p 2 2µsec IC301 2 0Vp p 2 1µsec ...
Page 36: ...MVC FD91 4 12 4 13 4 14 STEADY SHOT CONTROL VP 49 VP 49 BOARD 1 IC237 2 8Vp p 12MHz ...