5-3.
CHARGING VOLTAGE ADJUSTMENT
(See original service manual page 5-6)
Equipment
• Personal Computer (PC)
• Camera DSLR-A100
• USB Cord With Connector
• Flash Adjustment Program
Note:
Flash Adjustment Program is downloadable from the ESI homepage.
• DC Power Supply
• Digital Multimeter
• Power Supply Adaptor
• Voltage Confirmation Cable
*
Personal Computer
Digital multimeter
Power supply adaptor
USB cord with connector
DC power supply
(5.8 V, 1.8 A)
The probe (–) of the digital multimeter can be connected
to the negative line of the DC power supply.
Camera
Voltage confirmation cable
*
Fig. 5-3-1