background image

Easy Maintenance of Luminance 
Level

During long periods of usage, users commonly have to 
adjust the luminance level of their projector, as Xenon 
lamps typically get darker over time.  The SRX-R320P has a 
convenient function to help users know when to make such 
adjustments.  It allows users to set a standard luminance 
level, and displays an alert message on the LCD screen of 
the projector when the value changes from the standard 
level.  With this feature, proper and timely maintenance of 
the luminance level can be performed.

Automatic Lamp Power 
Calibration Function

When switching the aspect ratio of projection from 
CinemaScope to VistaVision and vice versa, the luminance 
levels happen to change.  To maintain a constant 
luminance level even after making these changes, the  
SRX-R320P can automatically calibrate the luminance level 
by controlling the lamp output power.

Air-flow Sensor for Reliable Cooling

The SRX-R320P has a chimney on top of the unit that expels 
warm air, thereby keeping the projector unit cool.  The 
chimney has an air-flow sensor that measures the amount 
of discharged air.  When the projector is powered on from 
Standby mode, the air-flow sensor operates automatically.  
If the value does not reach a normal level, an alert 
message is displayed on the projector’s LCD screen.  
Thanks to this function, the operator can immediately 
take proactive maintenance action, allowing for reliable 
projector cooling.

Power Supply and Control of 
External Ventilation Fan

To efficiently discharge warm air from the unit, the chimney 
of the SRX-R320P projector must be connected to an 
exhaust duct with a ventilation fan.  For optimum reliability 
and effectiveness, the projector supports an Interlock 
interface, which enables the SRX-R320P to operate this 
external ventilation fan.  The projector can supply power to 
the fan and control its operation – the fan works when the 
projector is in Lamp ON mode or Standby ON mode.

Key Lock System

The SRX-R320P is designed to be highly secure.  It does 
not have screw holes, and requires physical keys to open 
the enclosure.  This body structure meets the anti-tamper 
requirement of the DCI.  Even if the enclosure is opened 
with the physical keys, anti-tamper sensors will trigger the 
LMT-300 Media Block to immediately start recording logs for 
further safety.  In this case, the projector also deletes Key 
Delivery Messages (KDM) automatically, so that DCP files 
cannot be played back.

SRX Controller Software

The SRX Controller software* is a convenient tool for system 
integrators to set up and maintain the SRX-R320P.  This runs 
on a PC** connected to the projector via the RS-232C 
interface, and features intuitive GUIs that enable easy 
setup and adjustment of the projector.  A comprehensive 
range of setup parameters including input configurations, 
colorimetry controls, installation adjustments, and 
maintenance settings can be controlled via this software.
For example, it allows operators to easily verify a lamp’s 
operating time.  Plus, the versatile projector functions 
such as Squeeze Mode, Color Space Conversion (CSC), 
and Zoom/Focus Memory can also be controlled via this 
software. 

*  For detailed information on availability of the SRX Controller software, please 

contact your nearest Sony office.

** System requirements for the SRX Controller software: Microsoft

®

 Windows

®

 XP 

Professional.  Supported OS languages are English and Japanese only.

8

Maintenance and Security Features

Summary of Contents for LMT-300

Page 1: ...SRX R320P 4K Digital Cinema Projector LMT 300 Media Block STM 100 Theater Management System ...

Page 2: ...2 The Next Generation of 4K Digital Cinema ...

Page 3: ...tes hard disk drives HDDs with a large storage capacity of approximately 1 7 TB and adopts a reliable RAID Redundant Array of Inexpensive Disks system It can play back DCI DCP Digital Cinema Package files and allows the SRX R320P projector to show digital cinema programs Another unique feature of the LMT 300 is its Screen Management System function which is equipped as standard and can provide a v...

Page 4: ...theater audience In recent years stadium type seating is becoming increasingly popular among modern cinema complexes By sitting closer to the screen the audience can enjoy a more immersive visual experience However those sitting in the front rows may witness pixel artifacts when the resolution provided by the projection system is not sufficient to fill the screen size The SRX R320P provides true 4...

Page 5: ... lamp can be used for a 15 foot 4 5 meter wide screen Variety of High quality Lenses Five optional zoom lenses are available for the SRX R320P All lenses utilize very large image circles that contribute to minimizing the optical vignetting that typically occurs on projector lenses and to obtaining the highest possible values of MTF Modulation Transfer Function With these features the optical syste...

Page 6: ...pe images 4096 x 1716 pixels are input the SRX R320P extends them in a longitudinal direction via the projector s image processing function which effectively uses all the pixels of the SXRD device The LKRL A001 attached in front of the projector s lens extends the images in a transverse direction so that the aspect ratio of the images projected on a screen can be restored to its original 2 39 1 Th...

Page 7: ...cted images can be moved vertically by 50 to 50 and horizontally by 5 to 5 Keystone Masking To compensate for keystone distortion which typically occurs when the projector is not installed directly in front of the screen the SRX R320P has an image masking function To determine the best position for the masking this function allows users to set further two points in addition to the four corner poin...

Page 8: ...with a ventilation fan For optimum reliability and effectiveness the projector supports an Interlock interface which enables the SRX R320P to operate this external ventilation fan The projector can supply power to the fan and control its operation the fan works when the projector is in Lamp ON mode or Standby ON mode Key Lock System The SRX R320P is designed to be highly secure It does not have sc...

Page 9: ...hieved Sony has overcome this difficulty through the use of innovative planarization technology in the silicon backplane structure and an advanced silicon wafer based assembly process The SXRD device also adopts a structure that does not use spacers These are columns found in conventional reflective liquid crystal devices to maintain a constant gap between the liquid cell floor and the top of the ...

Page 10: ...dio DCP files into AES EBU digital audio signals and then outputs them from two audio output connectors D sub 25 pin to external audio processors such as Dolby sound processors The audio output 1 and audio output 2 can support up to 8 and 16 channels respectively The timing of the audio output can be adjusted for complete synchronization with the picture and any channel can be routed to any output...

Page 11: ...n and key management Show Play List SPL creation and management Show schedule viewing Playback control Execution of SPLs Device configuration Device monitoring Status monitoring collect status information from the projector and Media Block report status at pre configured intervals Monitoring of cavity security status from Media Block Automation system interface Projector Power On Standby control L...

Page 12: ...ssigned SPL lack of DCP KDM etc for schedule making Theater Management System STM 100 Creation of SPL Functions SPL creation and management Composition Play List CPL grouping functions to combine multiple compositions content programs such as trailers Customized SPL template with Cue output trigger Blank time insertion into SPL Automatically adjustable cue setting Manual transfer of SPL to auditor...

Page 13: ... 8 699 8 3 8 212 barycentric position 2 5 8 64 17 1 2 442 25 1 4 640 29 1 4 740 barycentric position 28 5 8 726 3 1 2 88 49 1 4 1250 6 7 8 174 1 1 4 31 Area necessary for cooling of LMT 300 9 1 2 241 8 3 4 222 23 1 4 590 27 5 8 699 3 4 19 barycentric position 11 32 8 ø7 7 8 198 barycentric position for LKRL Z214 Dimensions Unit inches mm SRX R320P LMT 300 ...

Page 14: ...600 x 1200 WUXGA 1920 x 1200 HD 1920 x 1080 DC 2048 x 1080 Power consumption Max 5 4 kW USHIO DXL 40SRXPRO 4 2 kW lamp Max 4 2 kW 3 0 kW lamp Max 3 0 kW 2 0 kW lamp Power requirements AC 200 V to 240 V 50 60 Hz single phase 27 A to 22 5 A Operating temperature 41 F to 95 F 5 C to 35 C Operating humidity 35 to 85 no condensation Storage temperature 12 F to 140 F 20 C to 60 C Dimensions 27 5 8 x 25 ...

Page 15: ...5024 ITE EN61000 3 2 61000 3 3 IEC60950 1 AS NZS CISPR22 EN55022 Class A JIS C 61000 3 2 Supplied accessories Plug holder 1 Screw 4 D sub 9 pin connecting cable 3 m 1 Terminal board socket 10 pin 1 Operating instructions 1 Front panel Front view without front panel Rear panel LKRL Z211 LKRL Z214 LKRL Z219 LKRL Z119 LKRL Z122 Z00m Ratio 1 67x 1 82x 2 16x 1 6x 1 8x Throw ratio 1 05 1 to 1 75 1 1 33 ...

Page 16: ...ma Solutions 6080 Center Drive Los Angeles CA 90045 www sony com digitalcinema DI 0189A MK10626V2 2010 Sony Corporation All rights reserved Reproduction in whole or in part without permission is prohibited Features and specifications are subject to change without notice The values for weight and dimension are approximate Sony is a registered trademark of Sony Corporation Sony Digital Cinema and So...

Reviews: