— 22 —
KV-24FS100/25FS100
ADJUSTMENT ITEMS (5 OF 8)
DEVICE "RGB"
Item#
OSD
DETAIL
Range
(DEC)
Initial Data
1
AMUT
RGB POWER ON MUTE
00-01
0
2
PMUT
RGB MUTE(EXCEPT OSD)
00-01
1
3
VBLK
00-01
0
4
CORL
R CUTOFF lower
00-255
100
5
CORH
R CUTOFF upper
00-01
1
6
COGL
G CUTOFF lower when Color Temp. is "Cool" and "Neutral"
00-255
125
7
COGH
G CUTOFF upper when Color Temp. is "Cool" and "Neutral"
00-01
1
8
COBL
B CUTOFF lower when Color Temp. is "Cool" and "Neutral"
00-255
125
9
COBH
B CUTOFF upper when Color Temp. is "Cool" and "Neutral"
00-01
1
10
ABLS
ABL SELECT (ON:00, OFF:01)
00-01
0
11
ACLS
ACL ON (ON:00, OFF:01)
00-01
1
12
ALSP
ACL SPEED
00-03
1
13
ALRS
ACL RECOVER SPEED
00-15
2
14
ALAS
ACL ATACK SPEED
00-15
9
15
ABLG
ABL GAIN
00-15
15
16
ALS2
ACL ATACK SPEED(2)
00-03
2
17
AKBS
AKB MODE
00-01
1
18
AKBP
AKB PULSE HEIGHT
00-63
40
19
OSDL
OSD LIMMIT SELECT
00-01
0
20
MPXS
UV MULTIPLEX ON
00-01
0/YUV:0
21
CXUV
YC/YUV SELECT
00-01
0/YUV:1
22
UVIN
U/V INVERT
00-01
0/YUV:0
23
UVOS
UV OFFSET CANCELER ON
00-01
0/YUV:0
24
ACL
SOFT ACL CONTROLE
00-63
63
25
HBLS
H BLK OFF
00-01
0
26
VENS
V-latch OFF
00-01
0
27
UOFS
U IN OFFSET
00-15
4
28
VOFS
V IN OFFSET
00-15
9
29
AABL
ANALOG ABL THRESHOLD LEVEL CONTROL
00-15
0
30
AABG
ANALOG ABL GAIN CONTROL
00-01
0
31
AALG
ANALOG ACL GAIN CONTROL
00-01
0
32
AABS
ANALOG ABL ON/OFF CONTROL (ON:01, OFF:00)
00-01
0
33
AALS
ANALOG ACL ON/OFF CONTROL (ON:01, OFF:00)
00-01