– 84 –
KP-FWS57M90
RM-1007
5-1-9. PAL RF Input (Sub Picture)
1. Enter the PAL RF color bar (White & color 75%) signal.
(i) SUB CONTRAST
Condition :
Adjusting Parameter :
RIGHT
:
YCTS
02 SCON
(ii) SUB COL/SUB HUE (Sub Picture)
Condition :
Adjusting Parameter :
RIGHT
:
YCTS
03 SCOL
YCTS
04 SHUE
GND
VG2
VG1
Main
Sub
VG1 – VG2 = 1.60
±
0.03 Vp-p
VB4
VB3
VB1
VB2
Main
Sub
VB1 = VB4
±
70 mV
VB2 = VB3
±
70 mV
Category
Item
Data
PIC
00
PIC
100
01
COL
0
05
PIOF
0
MID2
02
BCOL
0 (TWIN 5-->0)
MCP
02
RON
0
03
GON
1
04
BON
0
15
ABLT
0 (TWIN 5-->0)
Category
Item
Data
PIC
01
COL
54
COLR
01
HUOF
3
MCP
02
RON
0
03
GON
0
04
BON
1