— 46 —
KP-46WT500
G BOARD
3-3. +B MAX VOLTAGE CONFIRMATION
The following adjustments should always be performed when replacing
IC501, R5032.
1. Supply 130VAC to variable autotransformer.
2. Receive dot signal pattern and set the PICTURE and BRIGHTNESS
settings to their minimum.
3. Confirm the voltage of TP +B 135V is less than 137.0Vdc.
4. If step 3 is not satisfied, replace IC501 and repeat steps 1-3.
3-4. +B OVP CONFIRMATION
1. Add to low voltage power supply between to TP5001 and ground.
2. Supply 120VAC to variable autotransformer.
3. Power on the Set and receive dot signal pattern.
4. Set the PICTURE and BRIGHTNESS settings.
5. Check the OVP is activated.
Operate :less than 2.50V