KE-61MR1 (K) 2-1
SECTION 2
ADJUSTMENTS
2-1. VS, VD Voltage Adjustment (PDM-6100)
2-1-1. Preparation for adjustment
1.
Slide the DIP switch (S3201) No. 8 of P board to on position
with no silkscreen mark
r
.
2.
Connect a digital voltmeter to the following terminals of G
board.
VS voltage=G board TP1701 (VS)-TP1502 (GND)
VD voltage=G board TP1501 (VD)-TP1502 (GND)
3.
Connect a AC cord in DISPLAY UNIT.
4.
Perform the adjustment in 10 seconds after connecting the
cord.
2-1-2. Procedure for adjustment
1.
Slide the DIP switch (S3201) No. 7 of P board to on position
with no silkscreen mark
r
.
2.
Confirm the lighting of SONY LOGO LED.
3.
Adjust the VS voltage to the following voltage value.
VS voltage of proper value for each model.
Ex.) VS proper value=185V thru 185.6V at 185V.
(Check the proper value with a seal on upper left of panel
unit. Refer to right Fig.)
4.
Adjust the VD voltage to the following voltage value.
VD voltage
±
0.3V of proper value for each model.
Ex.) VD proper value=64.7V thru 65.3V at 65.0V.
(Check the proper value with a seal on upper left of panel
unit. Refer to right Fig.)
5.
Check a Fan rotation.
6.
Slide the DIP Switch (S3201) No. 7 of P board to the off
position with the silkscreen mark
r
.
7.
Slide the DIP Switch (S3201) No. 8 of P board to the off
position with the silkscreen mark
r
.
8.
Disconnect an AC cord of DISPLAY UNIT.
9.
Reconnect the AC cord in one second.
10. Assure that “POWER ON/STANDBY” LEDs is flashing
amber.
+6V
–0V
Rear cover assy
SERIAL No.
301201440
Vd=65V
Vs=193.4V
CODE AA-01
BAR CODE SEAL
Panel unit
2-2. White Balance Adjustment (PDM-6100)
2-2-1. Measurement equipment
1.
Color analyzer (CA-100 manufactured by MINOLTA)
2.
Signal generator (ASTRO DESIGN VG-828D)
2-2-2. Measuring procedure
1.
Dab the W/B adjustment jig (CA-100) at the glass face of the
panel.
2.
Connect the Signal generator (VG-828D) to the DVI
terminal.
3.
Input All-white signal and set the picture mode to
DYNAMIC.
4.
Select”PNLCTRL” in the service mode menu and set “0
WBNO” at “0”
5.
Select “SCNR” “SCNB” of “PDPWB” in the service mode
menu, and then adjust following W/B standardized values
of 6500K, 8000K, 9300K, 10000K and 13550K to following
values of X/Y.
W/B standardized values:
6.
After adjusting the values, at the values of the “SCNR” or
“SCNB” exceeding 128 (initialize value).
1) Reset a lager value of the “SCNR” or “SCNB” at 128.
2) Set the White Balances with the last of items and “SCNG”
to the X/Y values above.
7.
After the above step, when these item are nonqualified
following conditions, set the largest one at 128 and readjust
the White Balance with the last two item.
1) No one of “SCNR”, “SCNB” and “SCNG” exceeding 128
2) Confirm the item value 128 at least one item
8.
As a result above, input the sequential number of value to the
“SCNR”, “SCNB” and “SCNG”.
9.
Repeat the same step 5 thru 8 for the W/B 1 thru 4 after
setting the “0 WBNO” at each W/B number.
10. Input following signals from the Signal generator (VG-
828D).
1) All-white signal (255/255) input
Y (luminance)=45cd/m
2
or more
2) 1/25Window (255/255) input
Y (luminance)=45cd/m
2
or more
• Service mode lists
Caution: 1. Setting functions of Display section are displayed
with yellow OSD.
2. Be careful not to set DATA in the yellow-covered
OSD menu. The setting will be memorized.
3.
items are not required adjustment or are banned
adjustment.
<SEAL POSITION>
6500K+8MPCD
0
0.3133
±
0.003
0.3297
±
0.003
8000K+8MPCD
1
0.2944
±
0.003
0.3100
±
0.003
W/B
X
Y
9300K+8MPCD
2
0.2838
±
0.003
0.2981
±
0.003
10000K
3
0.2806
±
0.003
0.2883
±
0.003
13550K
4
0.2684
±
0.003
0.2700
±
0.003