![Sony Jumbotron JME-UA200 Service Manual Download Page 24](http://html.mh-extra.com/html/sony/jumbotron-jme-ua200/jumbotron-jme-ua200_service-manual_400663024.webp)
1-20 (E)
JME-UA200
38
U N I T C O N T R O L
U n i t R e s e t
L E D C h e c k
C u r s o r C h e c k
U N I T T Y P E : L D U - 1 5
U N I T S P G
U N I T T y p e
R e v i s e D a t a
U N I T C o n d i t i o n
F a n S p e e d : F a s t
Checking the JumboTron Display Unit Functions
Checking the present conditions of the JumboTron display unit (Unit
Condition) (LDU-15 only)
1
Select “UNIT Condition” from the UNIT CONTROL menu.
The “Unit Condition” menu appears in the display window.
2
Select the screen No. and unit address to be checked.
Press the
◊
or
√
button to select “SCREEN No.” or “UNIT Address,”
change the item with the
∫
or
ı
button, and press the ENTER button.
The following items are displayed in the display window.
Item
Meaning
Fan Move (or Stop)
The fan in the unit is running (or stops).
Thermal OK (or NG)
The temperature inside the unit is normal (or abnormal).
12 V/6 V/4 V Power
The 12 V, 6 V and 4 V power line operations are normal
OK (or NG)
(or abnormal).
3
Press the UNIT CONTROL button to finish checking.
If the selected unit number or screen number does not exist or
the communication is not carried out correctly
The “Communication Error!” appears in the display window instead of the
data. Check the cause and try to repeat the steps above.
Changing the fan speed of a JumboTron display unit (Fan Speed) (LDU-
15 only)
1
Press the
◊
or
√
button to select “Fan Speed” from the UNIT
CONTROL menu.
2
Press the
∫
or
ı
button to select “Fast” or “Slow.”
The running speed of the fan will become faster when selecting “Fast,”
and will become slower when selecting “Slow.”
Checking the fan operation
Checking the internal temperature of the unit
Checking the 12 V power line
Checking the 6 V power line
Checking the 4 V power line
Fan speed
U N I T C O N T R O L
U n i t C o n d i t i o n
S c r e e n N o . A 1 1
U N I T T Y P E : L D U - 1 5
U n i t A d d r e s s : 0 1
F a n M o v e
T h e r m a l O K
1 2 V P o w e r O K
6 V P o w e r O K
4 V P o w e r O K
39
Specifications
Power requirements
100 to 240 V AC, 50/60 Hz
Current consumption 0.2 A
Dimensions
200
×
240
×
90 mm
(7
7
/
8
×
9
1
/
2
×
3
5
/
8
inches)
Mass
1.6 kg (3 lb 8 oz)
Operating temperature
0°C to 45°C (32°F to 113°F)
Operating humidity
30% to 70%
Input/output
SIGNAL OUT: D-sub 15-pin
SENSOR: Half-pitch 20-pin
COM: D-sub 9-pin
Supplied accessories
Signal cable (2 m) (2)
AC power cord (3)
Operation Manual (1)
Design and specifications are subject to change without notice.
Summary of Contents for Jumbotron JME-UA200
Page 1: ...JME UA200 World UNIT ALIGNMENT CONTROLLER SERVICE MANUAL MODEL DEST ...
Page 3: ......
Page 28: ......
Page 30: ......
Page 34: ......
Page 42: ......
Page 52: ...9 10 9 10 JME UA200 UCK UCK UCK B SIDE SUFFIX 11 UCK A SIDE SUFFIX 11 ...
Page 54: ......
Page 55: ......