![Sony Jumbotron JME-UA200 Service Manual Download Page 23](http://html.mh-extra.com/html/sony/jumbotron-jme-ua200/jumbotron-jme-ua200_service-manual_400663023.webp)
1-19 (E)
JME-UA200
36
JTU-17
G1V: The revised voltage data of each dot for the selected position are
displayed.
Press
∫
button to display the data for four dots on the right, or
ı
button to
display those on the left .
REF: The standard voltage data of each cell are displayed.
LDU-15
If-Data: The revised voltage data of each dot for the selected position are
displayed.
If-Range: The current range data for each cell are displayed.
Checking the JumboTron Display Unit Functions
Data of each dot
Dot number (1–4)
Left
B, R, G
Data of each dot
Dot number (5–8)
Right
B, R, G
Data for each cell
Cell number
(horizontal)
Cell number (vertical)
Data of each dot
B
1 R
G
1
1 F
1 F
1 F
2
1 F
3
1 F
4
L
1 F
B
2 R
G
1 F
1 F
1 F 1 F 1 F 1 F
1 F 1 F 1 F
1 F 1 F 1 F
1 F 1 F 1 F
1 F 1 F 1 F
B
3 R
G
1 F
1 F
1 F
1 F 1 F 1 F
B
4 R
G
1 F
1 F
1 F 1 F 1 F 1 F
1 F 1 F 1 F
1 F 1 F 1 F
1 F 1 F 1 F
1 F 1 F 1 F
B
1R
G
5
1F
1F
1F
6
1F
7
1F
8
R
1 F
B
2 R
G
1 F
1 F
1 F 1 F 1 F 1 F
1 F 1 F 1 F
1 F 1 F 1 F
1 F 1 F 1 F
1 F 1 F 1 F
B
3 R
G
1 F
1 F
1 F
1 F 1 F 1 F
B
4 R
G
1 F
1 F
1 F 1 F 1 F 1 F
1 F 1 F 1 F
1 F 1 F 1 F
1 F 1 F 1 F
1 F 1 F 1 F
Dot number
B, R, G
B
1 R
G
1
1 F
1 F
1 F
2
1 F
3
1 F
4
1 F
B
2 R
G
1 F
1 F
1 F 1 F 1 F 1 F
1 F 1 F 1 F
1 F 1 F 1 F
1 F 1 F 1 F
1 F 1 F 1 F
B
3 R
G
1 F
1 F
1 F
1 F 1 F 1 F
B
4 R
G
1 F
1 F
1 F 1 F 1 F 1 F
1 F 1 F 1 F
1 F 1 F 1 F
1 F 1 F 1 F
1 F 1 F 1 F
B
1R
G
1
01
01
01
2
01
3
01
4
01
B
2R
G
01
01
01 01 01 01
01 01 01
01 01 01
01 01 01
01 01 01
B
3R
G
01
01
01
01 01 01
B
4R
G
01
01
01 01 01 01
01 01 01
01 01 01
01 01 01
01 01 01
Data of each dot
Dot number
B, R, G
R E F
1
2
3
1
F F
F F
F F
2
F F
F F
F F
3
F F
F F
F F
4
F F
F F
F F
37
To check the present HV current value (JTU-35, JTU-17 only)
The HV (High Voltage) current of the JumboTron display unit is measured
and displayed in the display window.
In step 2 on page 34, set “SCREEN No. (JTU-17 only) and “UNIT
Address,” then select “Ip” to display the data.
The unit measures the HV current, and the measured value is displayed in
the display window.
To check for defective cells (JTU-35, JTU-17 only)
The JumboTron display unit checks for defective cell and shows it in the
display window.
In step 2 on page 34, set “SCREEN No.” (JTU-17 only) and “UNIT
Address,” then select “CELL Down” to display the data in the display
window.
HV current value
U N I T C O N T R O L
C e l l D o w n
S C R E E N N o . A 1 1
U n i t A d d r e s s : 0 1
U N I T T Y P E : J T U - 3 5
M O D E : C e l l D o w n
1 O K O K O K O K
2 O K O K O K O K
3 O K O K O K O K
U N I T T Y P E : J T U - 3 5
A d d r e s s : 0 1
1 2 3 4
U N I T C O N T R O L
I P
S C R E E N N o . A 1 1
U n i t A d d r e s s : 0 1
U N I T T Y P E : J T U - 3 5
C u r r e n t : 8 . 6 2 [ m A ]
Summary of Contents for Jumbotron JME-UA200
Page 1: ...JME UA200 World UNIT ALIGNMENT CONTROLLER SERVICE MANUAL MODEL DEST ...
Page 3: ......
Page 28: ......
Page 30: ......
Page 34: ......
Page 42: ......
Page 52: ...9 10 9 10 JME UA200 UCK UCK UCK B SIDE SUFFIX 11 UCK A SIDE SUFFIX 11 ...
Page 54: ......
Page 55: ......