– 5 –
ICX418AKL
DC Characteristics
Output circuit supply current
Item
I
DD
Symbol
5.0
Min.
Unit
Remarks
Typ.
Max.
mA
10.0
Bias Conditions 1 [when used in substrate bias internal generation mode]
Output circuit supply voltage
Reset drain voltage
Protective transistor bias
Substrate bias circuit supply voltage
Substrate clock
∗
1
V
L
setting is the V
VL
voltage of the vertical transfer clock waveform, or the same supply voltage as the V
L
power supply for the V driver should be used. (When CXD1267AN is used.)
∗
2
Do not apply a DC bias to the substrate clock pin, because a DC bias is generated within the CCD.
Item
V
DD
V
RD
V
L
V
DSUB
φ
SUB
Symbol
15.0
15.0
∗
1
15.0
∗
2
Min.
V
V
V
Unit
Remarks
Typ.
Max.
14.55
14.55
14.55
15.45
15.45
15.45
V
RD
= V
DD
Bias Conditions 2 [when used in substrate bias external adjustment mode]
Output circuit supply voltage
Reset drain voltage
Protective transistor bias
Substrate bias circuit supply voltage
Substrate voltage adjustment range
Substrate voltage adjustment precision
∗
3
V
L
setting is the V
VL
voltage of the vertical transfer clock waveform, or the same supply voltage as the V
L
power supply for the V driver should be used. (When CXD1267AN is used.)
∗
4
Connect to GND or leave open.
∗
5
The setting value of the substrate voltage (V
SUB
) is indicated on the back of the image sensor by a
special code. When adjusting the substrate voltage externally, adjust the substrate voltage to the indicated
voltage. The adjustment precision is ±3%. However, this setting value has not significance when used in
substrate bias internal generation mode.
V
SUB
code — one character indication
Code and optimal setting correspond to each other as follows.
Item
V
DD
V
RD
V
L
V
DSUB
V
SUB
∆
V
SUB
Symbol
15.0
15.0
∗
3
∗
4
Min.
V
V
V
%
Unit
Remarks
Typ.
Max.
14.55
14.55
6.0
–3
15.45
15.45
14.0
+3
V
RD
= V
DD
∗
5
∗
5
<Example> "L"
→
V
SUB
= 9.0V
V
SUB
code
Optimal setting
f
6.5
G
7.0
h
7.5
J
8.0
K
8.5
L
9.0
m
9.5
N
10.0
P
10.5
Q
11.0
S
12.0
U
13.0
V
13.5
W
14.0
R
11.5
T
12.5
E
6.0