8
Connection and Setup
System Connection
The unit accepts 4K signal or HD signal input connected using
BNC cables, and simultaneously outputs 4K signals and HD
signals converted to various formats.
Dual system signals can be processed at the same time, with
each system converted to independent signal formats.
Output signals are output in phase lock with the input
reference sync signal, or in phase lock with the channel A input
signal if there is no external reference sync signal.
1)
1) There is no genlock function for locking to the channel B input.
Always use an external reference sync signal or input a signal on
channel A that is used as a reference sync signal.
Connection example
I/O
I/O
HDRC-4000
HDRC-4000
4K INPUT
Link-1
4K OUT 1
Link-2
4K OUT 3
Link-3
4K OUT 5
Link-4
Link-1
Link-2
Link-3 Link-4
4K OUT 7
4K OUT 1 4K OUT 3 4K OUT 5 4K OUT 7
4K INPUT
Link-1 Link-2 Link-3 Link-4
Link-1 Link-2 Link-3 Link-4
HD INPUT
HD OUT
HD OUT
REFERENCE
LAN
Hub
RCP-1500 series
Remote Control Panel
MSU-1000/1500
Master Setup Unit
Reference sync
signal output
(loop through)
Channel B HD
input (3G/HD-SDI)
Reference sync
signal input
Channel A HD
input (3G/HD-SDI)
Channel A 4K input
1
4K Single-Link, 4K Dual-
Link, or 4K Quad-Link input
2
3G/HD-SDI×4 inputs
a)
External control
device
Channel A HD monitor output
(HD-SDI)
Channel A HD main output
(3G/HD-SDI)
Channel B HD main output
(3G/HD-SDI)
Channel B HD monitor output
(HD-SDI)
Channel B 4K output
1
4K Single-Link, 4K Dual-Link,
or 4K Quad-Link output
2
3G/HD-SDI×4 outputs
Channel A 4K output
1
4K Single-Link, 4K Dual-Link,
or 4K Quad-Link output
2
3G/HD-SDI×4 outputs
Channel B 4K input
1
4K Single-Link, 4K Dual-
Link, or 4K Quad-Link input
2
3G/HD-SDI×4 inputs
a)
a) For HD×4 input, input signals with priority on CH1 and CH3. If there is no input on CH1, CH2 to CH4 cannot be used. If there is no input
on CH3, CH4 cannot be used.