1-2
VPL-ES7
1-3. Disassembly
1-3-1. Upper Case Assembly
Upper case assembly
Screw
(+P
M3
x
6)
Loosen screw.
Lamp door
Two claws
Remove the filter
door in the direction
of the arrow
.
Front Side
of Unit
These portions are fragile.
Be very careful not to
damage them.
Five screws
(+P
M3
x
6)
Screw
(+P
M3
x
6)
Caution :
If the spacings in the top and bottom are not equal, go to “Assembling
method of optical unit assembly and Focus/Zoom adjust assembly”.
(Refer to section 1-3-8. Steps 9 to 14.)
Upon completion of the upper
case assembly attachment,
check to see that the spacing
in the top is equal to the
spacing in the bottom.
Zoom adjust gear knob
Press here strongly.
Remove the Upper case assembly
in the direction of the arrow.
Caution :
Remove the upper case assembly from this corner.
When attaching the upper case assembly, attach it while
aligning with the lower case pack assembly
starting from this corner.
Disengage the claws at
the 17 locations respectively.
Upper case assembly
Lower case pack
assembly
Front Side
of Unit
Lower case pack
assembly