![Sony HDCU1000 Maintenance Manual Download Page 12](http://html.mh-extra.com/html/sony/hdcu1000/hdcu1000_maintenance-manual_393436012.webp)
1-2 (E)
MM/HDCU1000 Series
When the conductive part is gold (HDCU1000)
Board
Flexible card wire
Board
Pin
Gold : Parts No.
CNB-21G
50
1-831-087-11
ADO-10G
CNB-21G
50
1-831-087-11
VIF-34G
CNB-21G
50
1-831-087-11
VIF-34G
CNB-21G
50
1-831-664-11
CN-2672G
CN-2805G
15
1-831-666-11
CN-2672G
SDI-86G
15
1-831-666-11
CN-2674G
When the conductive part is gold (HDCU1500)
Board
Flexible card wire
Board
Pin
Gold : Parts No.
AU-303G
45
1-831-665-11
MB-1072G
CNB-22G
50
1-831-087-11
ADO-10G
CNB-22G
50
1-831-087-11
VIF-34BG
CNB-22G
50
1-831-664-11
CN-2675G
CN-2677G
15
1-831-666-11
CN-2675G
SDI-87G
15
1-831-666-11
CN-2675G
When the conductive part is silver (HDCU1000)
Board
Flexible card wire
Board
Pin
Silver : Parts No.
CNB-21
50
1-830-799-11
ADO-10
CNB-21
50
1-830-799-11
VIF-34
CNB-21
50
1-830-799-11
VIF-34
CNB-21
50
1-830-798-11
CN-2672
CN-2805
15
1-830-801-11
CN-2672
SDI-86
15
1-830-801-11
CN-2674
When the conductive part is silver (HDCU1500)
Board
Flexible card wire
Board
Pin
Silver : Parts No.
AU-303
45
1-830-800-11
MB-1072
CNB-22
50
1-830-799-11
ADO-10
CNB-22
50
1-830-799-11
VIF-34B
CNB-22
50
1-830-798-11
CN-2675
CN-2677
15
1-830-801-11
CN-2675
SDI-87
15
1-830-801-11
CN-2675
1-2. Notes for Replacing Parts
There are two kinds of types (gold and silver) in the parts below used in this unit.
.
Flexible card wires
.
Boards
.
Connectors on the board (for flexible card wires)
When replacing the parts above, be sure to follow the instructions described in “1-2-1. Notes for Replacing the Flexible
Card Wire”, “1-2-2. Notes for Replacing the Board”, and “1-2-3. Notes for Replacing the Connector on the Board”.
Be sure to use the specified parts. Using un-specified parts causes the change in the characteristics of this unit and the unit
does not work properly.
Spare parts are listed in the spare parts list of “Spare Parts” Section. In the spare parts list, (GOLD) or (SILVER) is put
after each part name to distinguish two kinds of types (gold and silver).
1-2-1. Notes for Replacing the Flexible Card Wire
When replacing the flexible card wires listed below, confirm the conductive (terminal) part color of the flexible card wires
and follow the procedure below.
1.
Replace the flexible card wire with a flexible card wire whose conductive part is gold when the conductive part of a
flexible card wire is gold.
n
For the board on which a connector whose contact surface is gold is used, “G” is put after the board name by silk-
screen printing or a “G” seal is attached to the empty space on the board. Example: AU-303G
2.
Replace the flexible card wire with a flexible card wire whose conductive part is silver when the conductive part of a
flexible card wire is silver. In this case, silk “G” or a “G” seal is not put on the board name.
Summary of Contents for HDCU1000
Page 8: ......
Page 10: ......
Page 44: ......
Page 214: ...7 6 MM HDCU1000 Series 7 6 2 3 4 5 A B C D E F G H 1 AT 167 3 6 AT 167 3 6 ...
Page 244: ......
Page 260: ...7 52 MM HDCU1000 Series 7 52 2 3 4 5 A B C D E F G H 1 ...
Page 268: ...7 60 MM HDCU1000 Series 7 60 2 3 4 5 A B C D E F G H 1 ...
Page 276: ...7 68 MM HDCU1000 Series 7 68 2 3 4 5 A B C D E F G H 1 ...
Page 290: ...7 82 MM HDCU1000 Series 7 82 2 3 4 5 A B C D E F G H 1 ...
Page 296: ...7 88 MM HDCU1000 Series 7 88 2 3 4 5 A B C D E F G H 1 ...
Page 308: ......