SECTION 1
SERVICING NOTE
NOTES ON HANDLING THE OPTICAL PICK-UP BLOCK
OR BASE UNIT
The laser diode in the optical pick-up block may suffer electrostatic
break-down because of the potential difference generated by the
charged electrostatic load, etc. on clothing and the human body.
During repair, pay attention to electrostatic break-down and also
use the procedure in the printed matter which is included in the
repair parts.
The flexible board is easily damaged and should be handled with
care.
NOTES ON LASER DIODE EMISSION CHECK
The laser beam on this model is concentrated so as to be focused on
the disc reflective surface by the objective lens in the optical pick-
up block. Therefore, when checking the laser diode emission,
observe from more than 30 cm away from the objective lens.
LASER DIODE AND FOCUS SEARCH
1. Open the cover and turn POWER on with no disc inserted.
2. Confirm that the following operation is performed while
observing the objecting lens.
1)
Confirm that laser beam is spread.
2)
Up and down motion of the objective lens. (3 times)
DISC TRAY LOCK
The disc tray lock function for the antitheft of an demonstration
disc in the store is equipped.
Setting Procedure :
1. Press the
?/1
button to turn the set on.
2. Press the
[FUNCTION]
button to set DVD function.
3. Insert a disc.
4. Press the
x
button and the
A
button simultaneously for five
seconds.
5. The message “LOCKED” is displayed and the tray is locked.
Releasing Procedure :
1. Press the
x
button and the
A
button simultaneously for five
seconds again.
2. The message “UNLOCKED” is displayed and the tray is
unlocked.
Note 1:
When “LOCKED” is displayed, the tray lock is not released by
turning power on/off with the
?/1
button.
Note 2:
Incorrect operations may be performed if the test mode ia not
entered properly.
In this case, press the
?/1
button to turn the power off, and
retry to enter the test mode.
Note 3:
If the disc tray does not open and the message “LOCKED”
appears, press the
x
button and the
A
button simultaneously
for seconds or longer.
Then remove your fingers from the above stick and the button.
The message “UNLOCKED” appears for 2 seconds and the disc
tray opens.
Note on DMB12 board replacement
New part of EEP ROM (IC103, IC706) on the DMB12 board cannot be
used. Therefore, if the mounted DMB12 board (A-1148-813-A) is replaced,
exchange new EEP ROM (IC103, IC706) with that used before the
replacement.
When the self-diagnosis function is activated to
prevent the system from malfunctioning, a 5-
character service number (e.g., C 13 50) with a
combination of a letter and 4 digits appears on
the screen and the front panel display. In this
case, check the following table.
When displaying the version
number on the screen
When you turn on the system, the version
number [VER.X.XX] (X is a number) may
appear on the screen. Although this is not a
malfunction and for Sony service use only,
normal system operation will not be possible.
Turn off the system, and then turn on the system
again to operate.
Self-diagnosis Function
(When letters/numbers appear in the
display)
First 3
characters of
the service
number
Cause and/or corrective action
C 13
The disc is dirty.
,
Clean the disc with a soft cloth
C 31
The disc is not inserted correctly.
,
Restart the system, then re-insert
the disc correctly.
E XX
(xx is a number)
To prevent a malfunction, the
system has performed the self-
diagnosis function.
,
Contact your nearest Sony
dealer or local authorized Sony
service facility and give the 5-
character service number.
Example: E 61 10