5-36
3-4. VIDEO SYSTEM ADJUSTMENTS
Video system adjustments must be performed in the following order.
[Adjusting Order]
1.
28MHz origin oscillation adjustment
2.
AFC f
0
adjustment
3.
Filter f
0
adjustment
4.
Y OUT level adjustment
5.
C OUT level adjustment
6.
RP filter f
0
adjustment
7.
REC Y current adjustment
8.
REC L level adjustment
9.
REC C current adjustment
1. 28 MHz Origin Oscillation Adjustment (VC-214 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin
#™
of IC301 or pin
!™
of IC501
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
40
Specified Value
Pin
#™
of IC301 :
f=4433594 ± 17Hz
Pin
!™
of IC501 :
f=14187500 ± 55Hz
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 01, set data: 41, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 6, address: 61, and set data: 30.
4)
Select page: F, address: 40, change the data and set the clock
frequency (f) to the specified value.
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 6, address: 61, and set data: 10.
7)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
8)
Select page: 0, address: 01, and set data: 00.
2. AFC f
0
Adjustment (VC-214 board)
Adjust the pull-in range of the A/D converted clock generator during
playback.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin
4
of CN910 (AFC f0)
Measuring Instrument
Digital voltmeter
Adjustment Page
F
Adjustment Address
6A
Specified Value
A=2.00 ± 0.05Vdc
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 01, set data: 4D, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: F, address: 6A, change the data and set the DC
voltage (A) to the specified value.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
6)
Select page: 0, address: 01, and set data: 00.
IC501
1
12
36
25
24
37
13
48
IC301
1
16
48
33
49
32
64
17
VC-214 BOARD
Summary of Contents for Handycam Vision CCD-TRV66E
Page 11: ...1 2 ...
Page 12: ...1 3 ...
Page 13: ...1 4 ...
Page 14: ...1 5 ...
Page 15: ...1 6 ...
Page 16: ...1 7 ...
Page 17: ...1 8 ...
Page 18: ...1 9 ...
Page 19: ...1 10 ...
Page 20: ...1 11 ...
Page 21: ...1 12 ...
Page 22: ...1 13 ...
Page 23: ...1 14 ...
Page 24: ...1 15 ...
Page 25: ...1 16 ...
Page 26: ...1 17 ...
Page 27: ...1 18 ...
Page 28: ...1 19 ...
Page 29: ...1 20 ...
Page 30: ...1 21 ...
Page 31: ...1 22 ...
Page 32: ...1 23 ...
Page 33: ...1 24E ...
Page 46: ...CCD TRV66E TRV77E SECTION 3 BLOCK DIAGRAMS 3 1 OVERALL BLOCK DIAGRAM 3 1 3 2 3 3 3 4 ...
Page 54: ...CCD TRV66E TRV77E 3 9 POWER BLOCK DIAGRAM 3 29 3 30 3 31 3 32E ...
Page 56: ...CCD TRV66E TRV77E FRAME SCHEMATIC DIAGRAM 2 4 4 4 5 4 6 FRAME SCHEMATIC DIAGRAM 2 2 ...
Page 71: ...CCD TRV66E TRV77E 4 53 4 54 STEADY SHOT SE 83 AV IN OUT PJ 92 ...
Page 73: ...CCD TRV66E TRV77E 4 57 4 58 4 59 STEREO MIC AMP LASER LINK MA 351 ...
Page 79: ...CCD TRV66E TRV77E 4 75 4 76 4 77 USER CONTROL CF 56 MR 8500 ...
Page 82: ...CCD TRV66E TRV77E CCD TRV66E TRV77E 4 88E CONTROL SWITCH BLOCK FK 8500 SS 8500 ...