5-25
2. VCO Adjustment (PD-105 board)
Set the VCO free-run frequency. If deviated, the LCD screen will
be blurred.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin
2
of CN5501 (VCO VOLTAGE)
Measuring Instrument
Oscilloscope (DC range)
Adjustment Page
E
Adjustment Address
C2, D8
Specified Value
A = 1.70
+0.03
V
–0.05
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 01, set data: 55, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 6, address: 7D, and set data: 00.
4)
Select page: E, address: D8, change the data and set the VCO
VOLTAGE (A) to the specified value.
5)
Press the PAUSE button.
6)
Select page: E, address: D8 and read the data (D
D8
).
7)
Convert D
D8
to decimal notation, and obtain D
D8
'. (Refer to
Table 5-4-1. “Hexadecimal-decimal conversion table” of “5-4.
Service Mode”.)
8)
Calculate D
C2
' using following equation (decimal calculation),
convert it to a hexadecimal number, and input to page : E,
address : C2.
D
C2
' = D
D8
' – 27
9)
Press the PAUSE button.
10) Select page: 2, address: 01, set data: 00, and press the PAUSE
button.
11) Select page: 0, address: 01, and set data: 00.
3. D range Adjustment (PD-105 board)
Set the D range of the RGB decoder used to drive the LCD to the
specified value. If deviated, the LCD screen will become blackish
or saturated (whitish).
Mode
VTR stop
Signal
No signal
Measurement Point
Pin
3
of CN5501 (VG)
External trigger : Pin
4
of CN5501
(PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
E
Adjustment Address
D6
Specified Value
A = 3.06 ± 0.05V
Note :
Press the DISPLAY button and erase the screen indictors on the
LCD screen.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 01, set data: 55, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 6, address: 7D, and set data: 00.
4)
Select page: E, address: D6, change the data and set the voltage
(A) between the reversed waveform pedestal and non-reversed
waveform pedestal to the specified value.
5)
Press the PAUSE button.
6)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button.
7)
Select page: 0, address: 01, and set data: 00.
A
2H
Pedestal
Pedestal
H
A
GND level
(0Vdc)
Fig. 5-1-17.
Fig. 5-1-18.
Summary of Contents for Handycam Vision CCD-TRV66E
Page 11: ...1 2 ...
Page 12: ...1 3 ...
Page 13: ...1 4 ...
Page 14: ...1 5 ...
Page 15: ...1 6 ...
Page 16: ...1 7 ...
Page 17: ...1 8 ...
Page 18: ...1 9 ...
Page 19: ...1 10 ...
Page 20: ...1 11 ...
Page 21: ...1 12 ...
Page 22: ...1 13 ...
Page 23: ...1 14 ...
Page 24: ...1 15 ...
Page 25: ...1 16 ...
Page 26: ...1 17 ...
Page 27: ...1 18 ...
Page 28: ...1 19 ...
Page 29: ...1 20 ...
Page 30: ...1 21 ...
Page 31: ...1 22 ...
Page 32: ...1 23 ...
Page 33: ...1 24E ...
Page 46: ...CCD TRV66E TRV77E SECTION 3 BLOCK DIAGRAMS 3 1 OVERALL BLOCK DIAGRAM 3 1 3 2 3 3 3 4 ...
Page 54: ...CCD TRV66E TRV77E 3 9 POWER BLOCK DIAGRAM 3 29 3 30 3 31 3 32E ...
Page 56: ...CCD TRV66E TRV77E FRAME SCHEMATIC DIAGRAM 2 4 4 4 5 4 6 FRAME SCHEMATIC DIAGRAM 2 2 ...
Page 71: ...CCD TRV66E TRV77E 4 53 4 54 STEADY SHOT SE 83 AV IN OUT PJ 92 ...
Page 73: ...CCD TRV66E TRV77E 4 57 4 58 4 59 STEREO MIC AMP LASER LINK MA 351 ...
Page 79: ...CCD TRV66E TRV77E 4 75 4 76 4 77 USER CONTROL CF 56 MR 8500 ...
Page 82: ...CCD TRV66E TRV77E CCD TRV66E TRV77E 4 88E CONTROL SWITCH BLOCK FK 8500 SS 8500 ...