5-12
CCD-TRV107E/TRV108E/TRV208E/TRV408E
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENTS” are
satisfied.
1. HALL Adjustment
For detecting the position of the lens iris, adjust AMP gain and
offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
30, 31, 32
Specified Value 1
86 to 8A
Specified Value 2
15 to 19
Note1:
Displayed data of page 1 of the adjustment remote commander.
1 : 00 : XX
IRIS display data
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
94
88
Set the data.
3
6
95
17
Set the data.
4
6
01
6D
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”. (Note2)
6
6
01
00
Set the data, and press PAUSE
button.
Note2:
The adjustment data will be automatically input to page: F, address:
30, 31, 32.
Checking method:
Order Page Address Data
Procedure
1
0
03
03
Set the data.
2
6
01
01
Set the data, and press PAUSE
button.
3
1
Check that the IRIS display data
(Note1) satisfies the specified
value 1.
4
6
01
03
Set the data, and press PAUSE
button.
5
1
Check that the IRIS display data
(Note1) satisfies the specified
value.2.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
94
00
Set the data.
2
6
95
00
Set the data.
3
6
01
00
Set the data, and press PAUSE
button.
4
0
03
00
Set the data.
5
0
01
00
Set the data.
RadarW
RadarW
RadarW