5-32
4. Overall Noise Level Check
Mode
Recording and playback
Signal
No signal: Insert a shorting plug in the
AUDIO jack left and right
Measurement Point
AUDIO jack left or right
Measuring Instrument
Audio level meter
Specified Value
Below –45dBs
(IHF-A filter ON, 20kHz LPF ON)
Checking Method
1)
Insert a shorting plug in the AUDIO jack left and right.
2)
Record in the signal.
3)
Playback the recorded section.
4)
Check that the noise level is the specified value.