5-39
5-4. SERVICE MODE
4-1.
ADJUSTMENT REMOTE COMMANDER
The adjustment remote commander is used for changing the
calculation coefficient in signal processing, EVR data, etc. The
adjustment remote commander performs bi-directional
communication with the unit using the remote commander signal
line (LANC). The resultant data of this bi-directional communication
is written in the non-volatile memory.
1. Using the adjustment remote commander
1)
Connect the adjustment remote commander to the LANC
terminal.
2)
Set the HOLD switch of the adjustment remote commander to
“HOLD” (SERVICE position). If it has been properly
connected, the LCD on the adjustment remote commander will
display as shown in Fig. 5-4-1.
Fig. 5-4-1.
3)
Operate the adjustment remote commander as follows.
• Changing the page
The page increases when the EDIT button is
pressed, and decreases when the EDIT SEARCH– button is
pressed. There are altogether 16 pages, from 0 to F.
• Changing the address
The address increases when the FF (
)
) button is pressed,
and decreases when the REW (
0
) button is pressed. There
are altogether 256 addresses, from 00 to FF.
• Changing the data (Data setting)
The data increases when the PLAY (
(
) button is pressed,
and decreases when the STOP (
p
) button is pressed. There
are altogether 256 data, from 00 to FF.
• Writing the adjustment data
The PAUSE button must be pressed to write the adjustment
data (C, D page) in the nonvolatile memory. (The new
adjusting data will not be recorded in the nonvolatile memory
if this step is not performed.)
4)
After completing all adjustments, turn off the main power
supply (8.4V) once.
Page
Data
Address
Hexadecimal
notation
LCD Display
Decimal notation
conversion value
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 8 9 A b c d E F
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
2. Precautions upon using
the adjustment remote commander
Mishandling of the adjustment remote commander may erase the
correct adjustment data at times. To prevent this, it is recommended
that all adjustment data be noted down before beginning adjustments
and new adjustment data after each adjustment.
Summary of Contents for GV-D300 Operating Instructions (primary manual)
Page 9: ...1 2 ...
Page 10: ...1 3 ...
Page 11: ...1 4 ...
Page 12: ...1 5 ...
Page 13: ...1 6 ...
Page 14: ...1 7 ...
Page 15: ...1 8 ...
Page 16: ...1 9 ...
Page 17: ...1 10 ...
Page 18: ...1 11 ...
Page 19: ...1 12 ...
Page 20: ...1 13 ...
Page 21: ...1 14 ...
Page 22: ...1 15 ...
Page 23: ...1 16 ...
Page 24: ...1 17 ...
Page 25: ...1 18 ...
Page 26: ...1 19 ...
Page 27: ...1 20E ...
Page 30: ...2 3 2 4 CB 61 RJ 77 BOARDS 2 5 CONTROL SWITCH BLOCK FK 71 ...
Page 33: ...2 6E 2 12 CIRCUIT BOARDS LOCATION ...
Page 61: ...GV D300 D300E D900 D900E 4 85 4 86 4 87 AV IN OUT IO 62 4 88 ...
Page 62: ...GV D300 D300E D900 D900E 4 89 4 90 4 91 4 92 MULTI CONNECTOR EX 34 ...
Page 64: ...GV D300 D300E D900 D900E 4 96E CUSTOMER CONTROL CONTROL SW BLOCK FK 71 4 95 ...
Page 142: ...3 BLOCK DIAGRAMS PAGE 3 3 3 1 OVERALL BLOCK DIAGRAM 1 2 PAGE 3 8 3 3 POWER BLOCK DIAGRAM ...