4.INSTALLATION

4.INSTALLATION

Video Cable

coaxial cable with 75

impedance with copper conductor at center conductor, and

shielded with  95% copper. The following table shows different cable type and its
maximum length:

Ω

The values are for reference only.
Depends on the cable quality and
environmental condition, the
transmission distance might be less.

Cable standard

100m / 300 ft

Max. Distance (m /ft )

RG 59 /U

If the cable length is more than 100 m, it is recommended to use optional
accessories, such as Video Amplifier or Fiber Trassmission Converter,
for boost the Video Signal.

Fiber receiver
(optional)

Real time

HD-SDI DVR Center

(optional)

HD-SDI Monitor
(optional)

HD-SDI High Speed Dome

Up to 20km, Fiber cable

Extend connection distance with
Fiber Transmission

Fiber  transmitter
(optional)

Star-Connection

The star-form connection is mostly used. it enables the connection of different dome
cameras in longer distance. It is recommended to use RS-485 distributor to ensure
the telemetric data transmission:

The advantage of star-connection is
that every channel can work
independently and take a cable
length up to 1000 meters( depends
on cable quality). In case more
dome camera are installed, the star-
connection can be extended with
additional RS-485 distributors.

Some products may not be available in your country, please contact our distributor for more details

Some products may not be available in your country, please contact our distributor for more details

7

8

ENGLISH

RS-485

Distributor

RS-485 cable
up to 1000m
per channel

Termination
activated on
every end.

Video Amplifier
(optional)

Real time

HD-SDI DVR Center

(optional)

HD-SDI Monitor
(optional)

HD-SDI High Speed Dome

Up to 100m, coaxial cable

Extend connection distance with
Video Amplifier

Optional bracket accessories

The Indoor and Outdoor Model can be equipped with various bracket accessories for indoor
and outdoor installation. Please contact your distributor for further details.

Corner
Mount

Pole
Mount

Wall mount and

Power box

Ceilling
mount

Indoor Wall
mount

Outdoor
Power  Box

Indoor ceilling
mount

Extended wall
mount

Swan-Neck
Mounting
bracket

Wall
mount

Installing the core unit to base board.

The HD-SDI HSD Series core unit and base board are packed seperatly, in order to be
protected through the transportation. After unpaking and during the installation, the
core unit should be installed as following:

Installing the core unit by
pushing  into the
housing.please note the
position  of connector. For
releasing, please press the
lever-lock to core and pull off
the unit.

Lever-
Lock

Connector
Interface

Power
LED

Metal
Clip

WARNING:
Do not pull or hold the connector interface with force. It
is design only to connect the core unit and the base
board. Any presure on connector will cause damage and
avoids the warranty.

Safety spring

Rubber ring

cable

Heater connector

Once the base board is connected to power,
the power LED will light.

Heater connector
on outdoor
housing

Outdoor
housing cover

Screws

Indoor
embedded
mount

Summary of Contents for G65

Page 1: ...USER S MANUAL HD SDI High Speed dome Camera Series ...

Page 2: ...NTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE WARNING THIS IS A CLASS A PRODUCT IN A DOMESTIC ENVIRONMENT THIS PRODUCT MAY CAUSE RADIO INTERFERENCE IN WHICH CASE THE USER MAY BE REQUIRED TO TAKE ADEQUATE MEASURES CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PA...

Page 3: ...oids the warranty These will scratch the serface and affect the image qulaity Use the within 20 C to 60 C 4 F to 140 F and a humidity below 90 The input power source is 24V AC 50 60Hz and requires 2500mA outdoor models Do not expose the indoor model of dome camera to water or moisture not try to operate it in wet areas 2 FEATURES The HD SDI High speed dome camera series are designed for in and out...

Page 4: ... least 25mm This appliance has the lightning proof function which can prevent damages caused by high voltage pulse such as lightning strike below 1500 This appliance meets the Ip66 standard for water and dust proof Do not install the in door model for out door application which is not designed with water protection Make sure that the installation is protected from long time water drop or spatter w...

Page 5: ...5 cable The telemetric control of the appliance uses Rs485 serial communication with half duplex transmission technology Depends on the cable typeand baud rate the transmission distance could vary The following table shows max distances based on cable with 0 56mm 24AWG twisted pair 2400 bps 1100 m 700m 400m 4800 bps 1700m 9600 bps 19200 bps Baud Rate Max Distance Due the environmental interference...

Page 6: ...in your country please contact our distributor for more details 7 8 ENGLISH RS 485 Distributor RS 485 cable up to 1000m per channel Termination activated on every end Video Amplifier optional Real time HD SDI DVR Center optional HD SDI Monitor optional HD SDI High Speed Dome Up to 100m coaxial cable Extend connection distance with Video Amplifier Optional bracket accessories The Indoor and Outdoor...

Page 7: ... angle 0 359 Tilt deg Tilt angle 0 90 Zoom Factor Zoom factor Display of the information can be activate or deactivate through the OSD menu please refer to the system setting for detais OSD Menu How to start the OSD menu The HSD Series are equipped with new OSD Menu function All operation functions and camera related settings can be changed or modified here In order to use the OSD function a telem...

Page 8: ... L P A T T E R N S C L E A R A L L T O U R S C L E A R A L L W I N D O W S F A C T O R Y D E F A U L T S R E S T A R T B A C K E X I T T O U R T O U R R U N T O U R B A C K E X I T NUMBER 1 EDIT TOUR CLEAR TOUR W I N D O W N U M B E R 0 1 E D I T W I N D O W E N A B L E W I N D O W O N C L E A R W I N D O W B A C K E X I T W I N D O W B L A N K I N G ALARM NUMBER 001 ALARN ACTION NONE ACTIVATE AUX...

Page 9: ... BACK EXIT ADVANCE SETTING EIS ENABLED N A PRESET FREEZEN OFF AUTO FOCUS OFF DEFOGGER 015C HEAD UP OFF BACK EXIT CAMERA SETTING In camera setting menu you can setup camera module related settings please note that depends on module s capability some function may not available please contact your local sales representative for detailed information defines the speed when performing zoom function Acti...

Page 10: ...es PRESETS PRESET NUMBER 001 S E T P R E S E T S H O W P R E S E T C L E A R P R E S E T AUTO TRACKING ON E D I T P R E S E T L A B E L BACK EXIT PRESETS PRESET NUMBER SET PRESET SHOW PRESET G65 70 Series supports up to 128 presets The number can be selected from 0 to 128 Defining the preset points directly in OSD by entering this menu item and move the PTZ press IRIS OPEN key on the keyboard to s...

Page 11: ...ice to enter the preset point selection Move the joystick with up and down to select the preset points by number and save the setting with IRIS OPEN key with IRIS CLOSE key you can move to the previous selection If a select point has the value 0 all the following presets points will be ignored Starts the tour and exit the OSD menu EDIT TOUR TOUR DWELL 001 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ...

Page 12: ...0 9600 bps 0 1 19200 bps 1 1 SW 1 represent the domes address in binary form please refer to the list on next page for reference SW 2 Used for protocol settting and baud rate DIP 1 to 6 Protocol setting DIP 7 and 8 Baud rate setting Protocol DIP 1 2 3 4 5 6 VIDO B02 0 0 1 1 0 0 DIAMOND 1 0 0 1 0 0 HUNDA 1 0 1 1 0 0 KALATEL 0 1 0 1 0 0 LILIN 1 1 0 1 0 0 MOLYNX 0 0 1 0 0 0 PANASONIC 1 1 1 0 0 0 PELC...

Page 13: ...1 1 1 0 0 0 0 0 41 1 0 0 1 0 1 0 0 ID ID 0 0 0 0 0 0 0 0 0 1 0 0 0 1 0 0 34 Bit 1 2 3 4 5 6 7 8 Bit 1 2 3 4 5 6 7 8 0 0 1 0 0 0 1 0 0 1 1 0 0 1 1 0 1 0 1 0 0 0 1 0 1 1 1 0 0 1 1 0 0 1 1 0 0 0 1 0 0 0 0 1 0 1 1 0 1 1 1 0 0 0 1 0 1 0 0 1 0 1 1 0 0 0 0 1 0 0 1 0 0 1 0 1 0 1 1 0 1 0 0 1 0 0 1 0 1 1 0 1 0 1 1 0 0 1 0 1 0 0 1 0 0 0 1 1 0 1 1 0 1 1 0 1 0 0 1 0 1 0 1 1 0 1 1 0 0 0 1 1 0 0 1 0 0 1 1 1 0 1 ...

Page 14: ...179 170 180 181 182 183 184 185 186 187 188 189 190 191 193 178 194 195 196 197 198 199 200 201 202 203 192 Switchnumber Sw1 136 137 138 139 140 141 142 143 145 146 147 148 149 150 151 152 153 154 155 156 157 159 144 160 161 162 163 164 165 166 167 168 169 158 Switchnumber Sw1 Bit 1 2 3 4 5 6 7 8 0 0 1 1 0 0 1 1 0 1 1 1 0 1 1 1 1 0 1 1 0 0 1 1 1 1 1 1 0 1 1 1 0 1 1 1 0 0 1 1 0 0 0 0 1 1 1 1 1 1 1 ...

Reviews: