Basic Functions
FCB-EH6300(GB) A-E23-100-13(1)
Basic Functions
Overview of Functions
VISCA commands are the basis of camera control.
Timing Chart
As VISCA Command processing can only be carried
out one time in a Vertical cycle, it takes the maximum
1V cycle time for an ACK/Completion to be returned.
If the Command ACK/Completion communication
time can be cut shorter than the 1V cycle time, then
every 1V cycle can receive a Command.
Query Commands
General Commands
16 Byte
1) 1V cycle times on each Monitoring Mode and Shutter Speed.
Shutter Speed
Monitoring Mode
1080i/60/59.94
1080p/30/29.97
720p/30/29.97
720p/60/59.94
1/10000 sec to 1/60 sec
1/30 sec
1/60 sec
1/30 sec
1/30 sec
1/30 sec
1/15 sec
1/15 sec
1/15 sec
1/8 sec
1/8 sec
1/8 sec
1/4 sec to 1/1 sec
1/4 sec to 1/1 sec
1/4 sec to 1/1 sec
Shutter Speed
Monitoring Mode
1080i/50
1080p/25
720p/25
720p/50
1/10000 sec to 1/50 sec
1/25 sec
1/50 sec
1/25 sec
1/25 sec
1/25 sec
1/12 sec
1/12 sec
1/12 sec
1/6 sec
1/6 sec
1/6 sec
1/3 sec to 1/1 sec
1/3 sec to 1/1 sec
1/3 sec to 1/1 sec
In general
• Power On/Off
Powers the camera on and off. When the power is off,
the camera is able to accept only the lowest level of
VISCA Commands; the display and other features are
turned off.
• I/F Clear
Clears the Command buffer of the FCB camera.
• Address Set
VISCA is a protocol, which normally supports a daisy
chain of up to seven connected cameras via RS-232C
interface. In such cases, the address set command can
be used to assign addresses from 1 to 7 to each of the
seven cameras, allowing you to control the seven
cameras with the same personal computer.
Although the FCB camera does not support direct
connection of cameras in a daisy chain, be sure to use
the address set command to set the address whenever
a camera is connected for the first time.
• ID Write
Sets the camera ID.
• Mute
Blanks the screen and sends out a synchronizing
signal.
• Lens Initialize
Initializes the zoom and focus of the lens. Even when
power is already on, it initializes the zoom and the
focus.
Summary of Contents for FCBEH6500
Page 1: ... 2012 Sony Corporation Color Camera Module FCB EH6500 A EEP 100 11 1 Technical Manual ...
Page 57: ...57 Specifications DIGITAL Image Output Y Cb Cr 4 2 2 FORMAT Color coding complies with BT709 ...
Page 59: ...59 Specifications 1080p 30 Output Timing Chart 1080p 25 Output Timing Chart ...
Page 60: ...60 Specifications 720p 60 Output Timing Chart 720p 50 Output Timing Chart ...
Page 61: ...61 Specifications 720p 30 Output Timing Chart 720p 25 Output Timing Chart ...