2-9
SNC-CS20/CM120
4.
Check that “OK” is displayed in the upper right area of
the window, and then remove the color temperature
correction filter C14.
5.
Click the
[Next]
button.
2-2-10. White Balance Data Retrieving
(Light funnel) (Only SNC-CM120)
.
Subject:
Clear chart
.
Measuring equipment: Vectorscope
.
Specification:
None
1.
Check that the luminescent spot stays near the center
of vectorscope, and then click the
[3200K]
button.
2.
Put the color temperature correction filter C14 over the
lens.
3.
Check that the luminescent spot stays near the center
of vectorscope, and then click the
[5800K]
button.
SNC
_