![Sony EXWAVEPRO SNC-CM120 Service Manual Download Page 19](http://html.mh-extra.com/html/sony/exwavepro-snc-cm120/exwavepro-snc-cm120_service-manual_417981019.webp)
2-5
SNC-CS20/CM120
2-2-3. Setup Level Adjustment
.
Subject:
None
.
Measuring equipment: Waveform monitor
.
Specification:
NTSC: A = 7.5
±
2 (IRE)
PAL:
A = 0
±
14 (mV)
1.
Operate the spin box while checking the waveform
monitor to adjust the level to the specification A.
2.
Click the
[OK]
button.
3.
Check that “OK” is displayed in the upper right area of
the window, and then click the
[Next]
button.
2-2-4. Burst Level Adjustment
.
Subject:
None
.
Measuring equipment: Waveform monitor
.
Specification:
NTSC: B = 40
±
2 (IRE)
PAL:
B = 280
±
14 (mV)
1.
Operate the spin box while checking the waveform
monitor to adjust the level to the specification B.
2.
Click the
[OK]
button.
3.
Check that “OK” is displayed in the upper right area of
the window, and then click the
[Next]
button.
A
Spin box
SNC
_
CM120
B
Spin box
SNC
_
CM120
Summary of Contents for EXWAVEPRO SNC-CM120
Page 1: ...NETWORK CAMERA SNC CS20 SNC CM120 SERVICE MANUAL 1st Edition ...
Page 4: ......
Page 6: ......
Page 14: ......
Page 28: ......
Page 42: ......
Page 58: ......
Page 62: ......
Page 63: ......
Page 64: ...Printed in Japan Sony Corporation 2008 7 22 2008 SNC CS20 SY SNC CM120 SY E 9 968 462 01 ...