6-18
The following hidden commands are available. Data clear can be
confirmed from the fact that the screen display changes.
Clearing laser ON hours
Press [DISPLAY] and [CLEAR] keys on the standard commander
in this order.
Clearing emergency history
Press [TITLE] and [CLEAR] keys on the standard commander in
this order.
After repair is finished, always clear emergency history data.
Clearing Syscon preset
Press [DVD MENU] and [CLEAR] keys on the standard commander
in this order.
For EMG code, Mech mode, and Disc information of history dis-
play, see “Drvcon emergency code list”, “Drvcon Mech mode list”,
and “Drvcon disc status list”.
6-6. Other Checks
With the initial menu displayed, press [4] key on the standard com-
mander, and the information such as destination and ROM revision
will be displayed. At this time, LED and display tube lighting check
is also executed.
6-5. Emergency History
With the initial menu displayed, press [3] key on the standard com-
mander, and the information on emergency history of Drvcon and
Syscon will be displayed. This information is given over two pages,
which can be changed over with [1] and [2] keys. To return to the
initial menu, press [0] key.
After mode is selected, checksum calculation and information read-
ing are executed, thus requiring time before display.
Also, during this display, LEDs and display tube are all turned on.
The status of keys on standard commander and operation panel is
displayed in real time. However, if [POWER] key is pressed, the
power is turned off after display. Also, this mode is terminated if
pressing [RETURN] key.
The door is opened/closed by pressing [PANEL] key on operation
panel.
When [RETURN] key is pressed, LED and display tube are turned
off and the initial screen is resumed.
Note: A number of two decimal places of Rom Revision is a
design management code and therefore ignore it.
EMG. Hist Page.01
CD000000 Hour
EMGMech Disc TimeH TimeM TimeL
00 00 00 00 00 00
00 00 00 00 00 00
00 00 00 00 00 00
00 00 00 00 00 00
Page 1: 1Key
Page 2: 2Key
Exit : 0key
EMG. Hist Page.02
DVD000000 Hour
00 00 00 00 00 00
00 00 00 00 00 00
00 00 00 00 00 00
00 00 00 00 00 00
N
DVD laser ON hours
N
Emergency history (5)
of Drvcon
N
Emergency history (6)
of Drvcon
N
Emergency history (7)
of Drvcon
Emergency history (6)
of Syscon
Emergency history (5)
of Syscon
Emergency history (4)
of Syscon
Emergency history (3)
of Syscon
Emergency history (2)
of Syscon
Emergency history
(latest) of Syscon
Rom Revision
IF con Ver.x.xx (xxxx)
SYScon Ver.x.xx (xxxx)
DRVcon Ver.x.xx (xxxx)
Area Type (xx)
Region (xx)
SW1 OFF
SW2 OFF
SIRCS:ff KEY:ff RATE: 29
N
IFcon rev., checksum
N
Syscon rev., checksum
N
Drvcon rev., checksum
N
Destination of set
N
Set region number
N
Status of S001
N
Status of S002
N
IFcon internal information
Figure 21
N
Page
N
CD laser ON hours
N
Emergency history
of Drvcon (latest)
N
Emergency history (2)
of Drvcon
N
Emergency history (3)
of Drvcon
N
Emergency history (4)
of Drvcon
Figure 19
Figure 20
Page 1: 1Key
Page 2: 2Key
Exit : 0key
Summary of Contents for DVP-S3000 Operating Instructions / Mode d’emploi
Page 10: ...1 1 SECTION 1 GENERAL This section is extracted from US model instruction manual DVP S3000 ...
Page 11: ...1 2 ...
Page 12: ...1 3 ...
Page 13: ...1 4 ...
Page 14: ...1 5 ...
Page 15: ...1 6 ...
Page 16: ...1 7 ...
Page 17: ...1 8 ...
Page 18: ...1 9 ...
Page 19: ...1 10 ...
Page 20: ...1 11 ...
Page 21: ...1 12 1 12 E ...