6-1
SECTION 6
TEST MODE
6-1. Starting up Test Mode
With the DVP-S3000 in standby status, press [TIME], [CLEAR],
and [POWER] keys on the standard commander in this order. And,
the Test mode starts up and the initial menu shown in Figure 1 ap-
pears on the video display.
If [0] key on standard commander is pressed during initial menu
display, the Diagnosis screen as shown in Figure 2 is displayed, and
a checking starts from the top of diagnosis check items list sequen-
tially. After a checking started, standard commander keys are ac-
cepted while a message or title is blinking, so that you can go to the
next job.
Syscon Diagnosis
IF con
Ver.x.xx (xxxx)
SYScon
Ver.x.xx (xxxx)
DRVcon
Ver.0.00 (0000)
ROM Check
★★
Press Remocon Key
★★
SIRCS:ff KEY:ff RATE: 29
N
Data in ( ) indicates
Syscon checksum
Syscon Diagnosis
IF con
Ver.x.xx (xxxx)
SYScon
Ver.x.xx (0000)
DRVcon
Ver.0.00 (0000)
ROM Check
SIRCS:ff KEY:ff RATE: 29
In this mode, ROM revision number (Ver. No.) of each control IC
(MPU) and its checksum are displayed. However, Syscon checksum
and Drvcon value are obtained in the process of diagnosis check,
and therefore they are initially 0.
On the fifth line, an item is displayed, and IF control information is
displayed at the bottom though it is not related to a checking of
each item.
If Syscon Diagnosis is selected, a checking starts immediately, and
the result of initial ROM check and Syscon ROM checksum are
displayed as shown in Figure 3.
Test Mode Menu
0. Syscon Diagnosis
1. Drive Auto Adjustment
2. Drive Manual Operation
3. Emergency History
4.OtherChecks
Exit: POWER Key
Figure 1 Initial menu
In the Test mode, necessary operations are all done with the keys
on standard commander or operation panel.
The test mode can be finished and the set returns to the power off
status when the [POWER] key is pressed whichever mode, except
during checking of Syscon Diagnosis, you are working in now.
6-2. Syscon Diagnosis
In the Syscon Diagnosis, intermittent blocks such as 0-ff, 500-5ff,
a00-aff, f00-fff, 1400-14ff, etc. (address) are checked. All of the
operation are done with standard commander keys, and a menu can-
not be selected but all items are checked. After result display, you
can only select either “continue to next item” or “cancel”, and con-
tinue and retry in case of written data error are not available.
Figure 3
DVP-S3000
Figure 2
Summary of Contents for DVP-S3000 Operating Instructions / Mode d’emploi
Page 10: ...1 1 SECTION 1 GENERAL This section is extracted from US model instruction manual DVP S3000 ...
Page 11: ...1 2 ...
Page 12: ...1 3 ...
Page 13: ...1 4 ...
Page 14: ...1 5 ...
Page 15: ...1 6 ...
Page 16: ...1 7 ...
Page 17: ...1 8 ...
Page 18: ...1 9 ...
Page 19: ...1 10 ...
Page 20: ...1 11 ...
Page 21: ...1 12 1 12 E ...