1-5. Installation Space
Installation
Section 1
Installation
1-1. Installation Procedure
Installation procedure of this unit is shown on the follow-
ing flowchart.
Refer to each section about detail of each flow.
The operation manual is also reqruired to do
*
-marked
flow.
1-2. Supplied Accessories
Cap, BNC ........................................................................ 11
Cap, DC OUT .................................................................... 2
Cap, XLR (F) ..................................................................... 2
Cap, XLR (M) ................................................................... 5
Cap, DUST ........................................................................ 1
Shoulder belt assembly ...................................................... 1
Rear panel cover ................................................................ 1
Operation manual .............................................................. 1
Installation manual ............................................................ 1
n
After installation, be sure to use the supplied caps for
protecting unused connectors.
1-3. Operating Conditions
c
Do not block an air vent. If ventilation is not enough, the
unit may be damaged due to increase the internal tempera-
ture of the unit.
.
Do not shove the unit into cramped place with poor
ventilation.
.
Be sure to make cleaning if a cooling fan is covered with
dust.
.
Replace a cooling fan periodically.
.
Do not place the unit on a longhaired carpet.
.
Do not cover the unit with cloth.
n
Good air circulaiton is essential to prevent internal heat
build-up. Place the unit in location with sufficient air
circulation.
Do not block the ventilation holes of the cabinet and the
front and rear panels.
Operating temperature: 0
d
C to 40
d
C
Operating humidity:
25% to 80% (Condensation not
allowed)
Storage temperature:
_
20
d
C to 60
d
C
Locations to avoid:
.
Areas where the unit will be exposed to direct sunlight
of any other strong lights.
.
Areas near heat sources.
.
Dusty areas or areas subject to vibration.
.
Areas with strong magnetic field.
.
Areas with much electrical noise.
.
Areas with much static electricity.
.
Areas that is impossible to find a specified room for
installation.
(Refer to Section “1-5. Installation Space” .)
.
Areas windtight.