1-9
DNW-A25WS/A25WSP
Settings for Monitor Output Headroom (for slit lands)
Output headroom ( ) : Factory setting
Channel
Ref.No.(Indication)
(20 dB)
18 dB
16 dB
L
SL501 (18 dB)
Open
Short
Open
SL502 (16 dB)
Open
Open
Short
R
SL601 (18 dB)
Open
Short
Open
SL602 (16 dB)
Open
Open
Short
Switches
n
Do not change settings of the factory-use switches.
Ref.No.
Description
Factory setting
S1-1 to S1-4
Factory use
OFF
1-8-2. RE-150 Board
n
For removing/reattaching the boards, refer to the maintenance manual, volume 1.
Slit Land
Ref.No.
Description
Factory setting
SL1
Selects how the power is derived when the battery and external power supply
Open
are used simultaneously
Open: Always derived from the external power supply
Short: Normally derived from the external power supply
When an input voltage is 10.5 V or below, automatically selects the battery
SL1
A
B
C
D
E
F
G
1
2
3
4
5
RE-150 Board (A Side)
RE-150 board
1-8. Settings for Internal Switches/Slit Lands
Summary of Contents for DNW-A25WS