92
C:21:00
Self-diagnosis display
5-digit display
Cause and/or Corrective Actions
• You are using a battery pack that is not an
“InfoLITHIUM” battery pack.
c
Use an “InfoLITHIUM” battery pack (p. 13, 98).
• Moisture condensation has occurred.
c
Eject the cassette and leave your camcorder for at least
1 hour to acclimatize (p. 103).
• The video heads are dirty.
c
Clean the heads using a cleaning cassette (optional) (p.
104).
• A malfunction other than the above that you can service
has occurred.
c
Eject the cassette and insert it again, then operate your
camcorder. Do not perform this operation if moisture
starts to condense (p. 103).
c
Disconnect the power cord of the AC Adaptor or
remove the battery pack. After reconnecting the power
source, operate your camcorder.
c
Replace the cassette.
• A malfunction that you cannot service has occurred.
c
Contact your Sony dealer or local authorized Sony
service facility and inform them of the 5-digit code.
(e.g. E:61:10)
If you are unable to rectify the problem even if you try corrective actions a few times,
contact your Sony dealer or local authorized Sony service facility.
Your camcorder has a self-diagnosis display
function.
This function displays the current condition
of your camcorder as a 5-digit code (a
combination of a letter and figures) on the
LCD screen or viewfinder. If a 5-digit code
appears, check the following code chart. The
last 2 digits (indicated by
ss
) will differ
depending on the state of your camcorder.
LCD screen or Viewfinder
Self-diagnosis display
• C:
ss
:
ss
You can service your camcorder
yourself.
• E:
ss
:
ss
Contact your Sony dealer or local
authorized Sony service facility.
C:04:
ss
C:21:
ss
C:22:
ss
C:31:
ss
C:32:
ss
E:61:
ss
E:62:
ss