5-19
11. Auto White Balance Standard Data Input
Subject
Clear chart
(Color bar chart standard picture
frame)
Adjustment Page
F
Adjustment Address
70 to 73
Note 1:
Perform “9. Color Reproduction Adjustment” before this
adjustment.
Note 2:
Check that the data of page: 2, address: 02 is 00. If not,
turn the power of the unit OFF/ON.
Switch setting:
1) STEADY SHOT (Menu display) ..................................... OFF
2) NIGHT SHOT switch ...................................................... OFF
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Wait for 2 seconds.
3) Select page: 2, address: 01, set data: 11, and press the PAUSE
button of the adjusting remote commander.
4) Select page: 2, address: 01, set data: 0D, and press the PAUSE
button of the adjusting remote commander.
(When the standard data is take in, the data will be automati-
cally input to page: F, address: 70 to 73)
5) Select page: 2, address: 02, and check that the data is “01”.
Processing after Completing Adjustments:
1) Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
2) Select page: 0, address: 01, and set data: 00.
3) Perform “Auto White Balance Adjustment”.
12. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility
will be poor.
Subject
Clear chart
(Color bar chart standard picture
frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
DDS displayed data of TV
Measuring Instrument
monitor (Note 2)
Adjustment Page
F
Adjustment Address
3A, 3B
Specified Value
R ratio: 2B40 to 2BC0
B ratio: 5E40 to 5EC0
Note 1:
Perform “Auto White Balance Reference Data Input” be-
fore this adjustment.
Note 2:
The right four digits of the displayed data at the right
bottom side of the TV monitor.
00 XXXX
→
Object data
Switch setting:
1) NIGHT SHOT switch ...................................................... OFF
Adjusting method:
1) Place the C14 filter for color temperature correction on the
lens.
2) Select page: 0, address: 01, and set data: 01.
3) Select page: D, address: 11, set data: 02, and press the PAUSE
button of the adjusting remote commander.
4) Select page: 2, address: 01, set data: 3F, and press the PAUSE
button of the adjusting remote commander.
5) Select page: 0, address: 03, and set data: 04.
6) Select page: F, address: 3A, change the data and adjust the
average value
of the DSS displayed data (Note 2) to the R ratio specified
value.
7) Press the PAUSE button of the adjusting remote commander.
8) Select page: 0, address: 03, and set data: 05.
9) Select page: F, address: 3B, change the data and adjust the
average value of the DSS displayed data (Note 2) to the B
ratio specified value.
10) Press the PAUSE button of the adjusting remote commander.
Processing after Completing Adjustments:
1) Select page: 0, address: 03, and set data: 00.
2) Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
3) Select page: D, address: 11, set data: 00, and press the PAUSE
button of the adjusting remote commander.
4) Select page: 0, address: 01, and set data: 00.
5) Perform “White Balance Check”.