5-13
5.
Flange Back Adjustment
(Using the mini-pattern box)
The inner focus lens flange back adjustment is carried out auto-
matically. If disordered, the focus will be deviated during auto/
manual focusing.
Subject
Siemens star chart with ND filter
for mini-pattern box (Note)
Measurement Point
Check operation on TV
Measuring Instrument
monitor
Adjustment Page
F
Adjustment Address
3E to 42, 76 to 7B
Note:
Siemens star chart used is a darker one.
Switch setting:
NIGHT SHOT switch ........................................................... OFF
Preparation:
Install the mini-pattern box as shown below.
Note:
The attachment lens is not used.
Fig. 5-4-1
Adjusting method:
1) Install the camera so that the distance between its lens surface
and mini-pattern box is less than 3 cm.
2) Align both heights of camera and mini-pattern box.
3) Make sure that the output voltage of regulated power supply is
11.29 ± 0.01Vdc.
4) Confirm that the center of Siemens star chart meets the center
of shot image screen with the zoom lens at TELE end and
WIDE end respectively.
5) Select page: 0, address: 01, and set data: 01.
6) Confirm that the data on page: F, addresses: 3E to 42, 76 to 7B
are initial values. (see table below)
7) Select page: 2, address: 02, and confirm that the data is “00”.
8) Select page: 2, address: 01, set data: 13, and press the PAUSE
button on the adjusting remote commander.
9) Select page: 2, address: 01, set data: 27, and press the PAUSE
button.
(The flange back adjustment is carried out, and the data are
automatically entered to page: F, addresses: 3E to 42, 76 to
7B.)
10) Select page: 2, address: 02, and confirm that the data changes
to “01”.
Processing after Completing of Adjustments:
1) Select page: 2, address: 01, set data: 00, and press the PAUSE
button.
2) Perform “Flange Back Check”.
Address
Data
Address
Data
3E
25
76
1B
3F
00
77
54
40
19
78
25
41
00
79
80
42
35
7A
10
7B
FF
3 cm or less
Camera
Mini-pattern box
Regulated power supply
11.29
±
0.01 Vdc, 3.5 A or more
Red (+)
Black (–)
Black (GND)
Yellow (SENS +)
White (SENS –)
No connection