ELECTRICAL ADJUSTMENTS
1.
Y OUT Level Adjustment
Set the Y signal output level
Subject
Not required
Measurement Point
VIDEO output terminal
(75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
49
Specified Value
A = 286 ± 50 mV (NTSC)
A = 300 ± 50 mV (PAL)
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: F, address: 49, change the data and set the SYNC
level (A) to the specified value.
3) Press the PAUSE button of the adjusting remote commander.
Processing after Completing Adjustments:
1) Select page: 0, address: 01, and set data: 00.
Fig. 5-3-1
2.
C OUT Level Adjustment
Set the Chroma signal output level
Subject
Not required
Measurement Point
VIDEO output terminal
(75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
4B
Specified Value
A = 286 ± 50 mV (NTSC)
A = 300 ± 50 mV (PAL)
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: F, address: 4B, change the data and set the burst
level (A) to the specified value.
3) Press the PAUSE button of the adjusting remote commander.
Processing after Completing Adjustments:
1) Select page: 0, address: 01, and set data: 00.
Fig. 5-3-2