– 21 –
14. After the adjustment, load a disc only in slit 1, and press the
1/
u
button to turn off the power.
15. Press the
1/u
button while pressing the PUSH ENTER button
to turn on the power.
16. If the rotary table makes one round, and “YES” is displayed on
the fluorescent indicator tube after it stops, it means that the
adjustment has been performed properly.
Adjustment value 1:
At the shoulder part of waveform D1, T1 becomes H and T2 be-
comes L, and at the same time, the Y width must not be smaller
than 1/4 of the Z width.
In order to satisfy this value more easily, adjust so that X=Y ap-
proximately and observe the deviation of the waveform.
Adjustment value 2:
At the shoulder part of waveform D1, T1 becomes L and T2 be-
comes H, and at the same time, the Y width must not be smaller
than 1/4 of the Z width.
Adjustment Location :
[ BD BOARD ] – Side B –
IC102
IC103
TP
(RF)
TP
(FE1)
TP
(TE)
TP
(VC)
[ MAIN BOARD ] – Component Side –
1
6
RV501
DISC SENSOR
ADJUSTMENT
CN506
TP2
(AFADJ)
TP1
(ADJ)
R540
IC501
R531