– 10 –
SECTION 4
TEST MODE
4-1. DISPLAY CHECK MODE
With the power turned off (standby state), press the
1/u
button
while pressing the
P
(pause) button.
All FL segments and grids light up together with the
·
(play),
P
(pause), and STANDBY LEDs.
At the same time, the GROUP LEDs are lights up simultaneously.
Note: To exit this mode, press the
p
(stop) button.
4-2. ADJ MODE
1. Turn ON the power of the unit, set disc to disc table, and per-
form chucking.
2. Disconnect the power supply plug from the outlet.
3. To set ADJ mode, connect the test point (ADJ) of the MAIN
board to Ground, and connect the power supply plug to the outlet.
The power will turn on automatically, and the first track will be
played.
In this mode, table rotation and loading operations are not performed
because it is taken that the disc has already been chucked.
Note: The same operations are also performed in the following when
the test point (ADJ) is connected to Ground after turning on
the power.
• Direct search (movement of sledding motor) is not performed dur-
ing accessing
• Ignored even when GFS becomes L
• Ignored even when the Q data cannot be read
• Focus gain does not decrease
• Spindle gain does not decrease
• Servo related settings can be set manually and checked (Refer to
ADJ Mode Special Functions Table)
ADJ Mode Special Functions Table
(The buttons shown with ( ) function by using the sup-
plied remote commander only)
4-3. KEY AND DISPLAY CHECK MODE
To set this mode, connect the test point (AFADJ) on the MAIN
board to Ground, and connect the power supply plug to the outlet.
• All FL segments and grids will light up. (All lit check)
When a button is pressed, the types of buttons pressed until then
will be displayed on the left side and the number of the buttons
will be displayed on the right side. However, these will not be
displayed for the following special buttons.
p
(stop) button: FL segment check
(Refer to FL Tube Check Patterns)
P
(pause) button: FL grid check
(Refer to FL Tube Check Patterns)
The pause LED also lights up simultaneously.
·
(play) button: All FL segment and grid will light up.
The play LED also lights up simultaneously.
FL Tube Check Patterns
Segment check
• When the jog dial is rotated to the right, the GROUP LEDs light
up in the order of 1
n
2..8
n
1.
• When the jog dial is rotated to the left, the GROUP LEDs light up
in the order of 8
n
7..1
n
8.
• Abbreviation
FL: Fluorescent Indicator Tube
[ MAIN BOARD ] – Component Side –
Button
CONTINUE
SHUFFLE
PROGRAM
GROUP 1 (1)
GROUP 2 (2)
GROUP 3 (3)
GROUP 4 (4)
GROUP 5 (5)
GROUP 6 (6)
GROUP 7 (7)
GROUP 8 (8)
(9)
(10/0)
CHECK
CLEAR
Function
Servo average display
Displays VC, FE, RF, TE and traverse in hexadecimal
numbers
Focus bias display
Each time this is pressed, the focus bias is switched
between 1 and 2
(1)
Bias actually set Optimum bias Minimum jitter
(2)
U:Upper aliasing bias L:Lower aliasing bias
Auto gain display
Displays focus, tracking, sledding in hexadecimal
numbers
Increases the focus bias in 8 steps.
Sets the focus bias in the middle of aliasing.
Turns off the tracking and sledding servo
Returns the auto gain to the initial value (30)
Turns off the focus servo
Decreases the focus bias in 8 steps.
Re-adjusts the focus bias
Turns on the tracking and sledding servo
Switches the focus servo gain between normal and down
FG. norm: normal, FG. down: down
Sets the focus bias to 0 (no bias)
Next, displays the jitter measured at the focus bias set
S-curve observation mode.
(Exits this mode when the
p
button is pressed.)
Automatic eccentric measurement
The results of measurement is displayed in
µ
m directly.
Grid check
Magnified
A
B
C
D
E
1
6
RV501
DISC SENSOR
ADJUSTMENT
CN506
TP2
(AFADJ)
TP1
(ADJ)
R540
IC501
R531