5-40
A
B
Duty = A/B
×
100 [%]
Center of movement
CH1
CH2
Enlargement
t1=0
±
10
µ
sec
CH1
CH2
Fig. 5-3-4.
Fig. 5-3-5.
3-2.
SYSTEM CONTROL SYSTEM ADJUSTMENT
1. Initialization of D, E, F, 7 Page Data
If the D, E, F, 7 page data is erased due to some reason, perform “1-
2. INITIALIZATION OF D, E, F, 7 PAGE DATA”, of “5-1.
CAMERA SECTION ADJUSTMENT”
3-3.
SERVO SYSTEM ADJUSTMENT
1. CAP FG Offset Adjustment (VC-251 board)
Set the Cap FG signal duty cycle to 50% to establish an appropriate
capstan servo. If deviated, the uneven rotation of capstan and noise
can occur in the LP mode.
Mode
Camera recording (SP mode)
Subject
Arbitrary
Measurement Point
CAP FG (Pin
8
of CN713 or Pin
8
of CPC connector of FP-262 flexible)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
64
Specified value
Duty = 50 ± 1 %
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
81
Set the data, and press PAUSE
button.
3
6
02
Check that the data changes to
“01”.
4
6
01
00
Set the data, and press PAUSE
button.
5
Check that Duty of CAP FG
signal satisfies the specified
value. If not, repeat steps 2 to 5.
6
0
01
00
Set the data.
2. Switching Position Adjustment (VC-251 Board)
If deviated in this case causes switching noise or jitter on the played
back screen.
Mode
Playback
Signal
Alignment tape:
For tracking adjustment
(WR5-1NP (NTSC))
(WR5-1CP (PAL))
Measurement Point
CH1: SWP (Pin
qh
of CN713 or Pin
qh
of CPC connector of FP-262
flexible)
CH2: PB RF (Pin
9
of CN713 or Pin
9
of CPC connector of FP-262
flexible)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
62, 63
Specified Value
t1= 0 ± 10µ sec
Note:
NTSC model:CCD-TR618/TR818/TRV49/TRV58/TRV68/TRV78/
TRV88/TRV98
PAL model: CCD-TR618E/TR718E/TR728E/TRV49E/TRV58E/
TRV59E/TRV78E/TRV98E
Adjusting Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
F
22
C0
Set the data, and press PAUSE
button.
3
F
62
Change the data and minimize
“t1”. (Coarse adjustment)
4
F
62
Press PAUSE button
5
F
63
Change the data and adjust so
that the switching position (t1)
becomes the specified value.
(Fine adjustment)
6
F
63
Press PAUSE button
7
F
22
80
Set the data, and press PAUSE
button.
8
0
01
00
Set the data.
Ver 1.1 2001. 04
Summary of Contents for CCD-CCD-TRV49E
Page 13: ...1 2 ...
Page 14: ...1 3 ...
Page 15: ...1 4 ...
Page 16: ...1 5 ...
Page 17: ...1 6 ...
Page 18: ...1 7 ...
Page 19: ...1 8 ...
Page 20: ...1 9 ...
Page 21: ...1 10 ...
Page 22: ...1 11 ...
Page 23: ...1 12 ...
Page 24: ...1 13 ...
Page 25: ...1 14 ...
Page 26: ...1 15 ...
Page 27: ...1 16 ...
Page 28: ...1 17 ...
Page 29: ...1 18 ...
Page 30: ...1 19 ...
Page 31: ...1 20 ...
Page 32: ...1 21 ...
Page 33: ...1 22 ...
Page 34: ...1 23 ...
Page 35: ...1 24E ...