5-14
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENTS” are
satisfied.
2. HALL Adjustment
For detecting the position of the lens iris, adjust AMP gain and
offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
38, 39, 3A
Specified Value 1
86 to 8A
Specified Value 2
15 to 19
Note1:
Displayed data of page 1 of the adjustment remote commander.
1 : 00 : XX
IRIS display data
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
94
88
Set the data.
3
6
95
17
Set the data.
4
6
01
6D
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”. (Note2)
6
6
01
00
Set the data, and press PAUSE
button.
Note2:
The adjustment data will be automatically input to page: F,
address: 38, 39, 3A.
Checking method:
Order Page Address Data
Procedure
1
0
03
03
Set the data.
2
6
01
01
Set the data, and press PAUSE
button.
3
1
Check that the IRIS display data
(Note1) satisfies the specified
value 1.
4
6
01
03
Set the data, and press PAUSE
button.
5
1
Check that the IRIS display data
(Note1) satisfies the specified
value.2.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
94
00
Set the data.
2
6
95
00
Set the data.
3
6
01
00
Set the data, and press PAUSE
button.
4
0
03
00
Set the data.
5
0
01
00
Set the data.
Note:
NTSC model: CCD-TR618/TR818/TRV49/TRV58/TRV68/TRV78/TRV88/TRV98
PAL model: CCD-TR618E/TR718E/TR728E/TRV49E/TRV58E/TRV59E/TRV78E/TRV98E
1. Lens Type Input
Distinguish the type of the lens being used for the camcorder, and
input data corresponding to the type.
Subject
Not required
Measurement Point
Display data of page 1 (Note)
Measuring Instrument
Adjustment remote commander
Adjustment Page
E
F
Adjustment Address
5C, 5D, 5E, 5F
2C
Note:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
65
Set the data, and press PAUSE
button.
3
0
03
19
Set the data.
4
1
Check that the data.
When the data is “0000”,
proceed to step 5.
(Glass lens type)
When the data is “0001”,
proceed to step 11.
(Plastic lens type)
5
E
5C
21
Set the data, and press PAUSE
button.
6
E
5D
84
Set the data, and press PAUSE
button.
7
E
5E
FC
Set the data, and press PAUSE
button.
8
E
5F
F7
Set the data, and press PAUSE
button.
9
F
2C
D6
Set the data, and press PAUSE
button.
10
Proceed to step 16.
11
E
5C
22
Set the data, and press PAUSE
button.
12
E
5D
51
Set the data, and press PAUSE
button.
13
E
5E
FD
Set the data, and press PAUSE
button.
14
E
5F
C4
Set the data, and press PAUSE
button.
15
F
2C
D7
Set the data, and press PAUSE
button.
16
6
01
00
Set the data, and press PAUSE
button.
17
0
03
00
Set the data.
18
0
01
00
Set the data.
Summary of Contents for CCD-CCD-TRV49E
Page 13: ...1 2 ...
Page 14: ...1 3 ...
Page 15: ...1 4 ...
Page 16: ...1 5 ...
Page 17: ...1 6 ...
Page 18: ...1 7 ...
Page 19: ...1 8 ...
Page 20: ...1 9 ...
Page 21: ...1 10 ...
Page 22: ...1 11 ...
Page 23: ...1 12 ...
Page 24: ...1 13 ...
Page 25: ...1 14 ...
Page 26: ...1 15 ...
Page 27: ...1 16 ...
Page 28: ...1 17 ...
Page 29: ...1 18 ...
Page 30: ...1 19 ...
Page 31: ...1 20 ...
Page 32: ...1 21 ...
Page 33: ...1 22 ...
Page 34: ...1 23 ...
Page 35: ...1 24E ...