XBR-65X950B 9
SECTION 2 - TROUBLESHOOTING
STANDBY LED BLINKING FLOWCHART
Protect
Shutdown.
Standby LED
Blinking
No
Yes
Power Supply
Board*
No
Yes
2X
Main Board*
3X
4X
No
Yes
5X
Yes
6X
No
7X
Imediately
LCD Panel/
LD Board*
TCON
(LCD Panel)*
Yes
No
After a while
Check ventilation
10X
HEM3 Board
8X
See Triage Chart
10X
HEM3 Board
9X
Tuner Board*
Main Board*
Power Supply
Board*
*For Part Number information, refer to
“Section 4 - Exploded View/Part Number Information” on page